Skip to content

Composite Test & Evaluation Honiton materials testing laboratory

Composite Test & EvaluationHoniton

UKAS schedule 7583 identifies Composite Test & Evaluation at Units 4 & 5 Kingsgate, Honiton, and says testing is performed there only. Its detailed scope covers named mechanical tests for fibre-reinforced plastic composites and structural adhesives.

Reviewed by Arc · About this review

Key facts

Testing at the Honiton address only
UKAS schedule 7583 lists Composite Test & Evaluation at Units 4 & 5 Kingsgate, Heathpark Industrial Estate, Duchy Road, Honiton, EX14 1YG and says testing is performed at the above address only.
Defined composite and adhesive scope
The schedule lists mechanical testing for fibre-reinforced plastic composites and structural adhesives.

Testing capabilities

Fibre-reinforced plastic composite mechanical tests

The schedule lists compressive, flexural, in-plane shear, interlaminar shear and tensile testing for fibre-reinforced plastic composites.

Structural adhesive mechanical tests

The schedule lists metal-to-metal peel, metal-to-honeycomb-core peel and single-lap-shear testing for structural adhesives.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
Published composite-test environment and force ranges23 ± 3 °C; humidity below a maximum of 60% RH; 0.1–250 kN for named compressive, flexural, in-plane-shear and tensile entries; 0.1–10 kN for interlaminar shearThese are the schedule’s named composite-test conditions and entries. Confirm the applicable method, specimen, conditioning and current suitability directly.

Access and contact

UKAS schedule 7583 lists Mrs Louise Yeo, 01404 549 293 and louise.yeo@compositetest.com. Confirm the applicable method, specimen, conditioning, reporting, availability and lead time directly.

Facility contact

Address
Units 4 & 5 Kingsgate, Heathpark Industrial Estate, Duchy Road
Honiton, EX14 1YG
United Kingdom
Telephone
01404 549 293

Standards and accreditation

ISO/IEC 17025:2017 accreditation
UKAS schedule 7583, issue 008 dated 30 August 2024, states ISO/IEC 17025:2017 accreditation for its detailed scope.

What to confirm with the facility

  • Confirm the material system, adhesive or composite form, specimen geometry, conditioning, requested test, force range, applicable standard, reporting, availability and lead time directly with Composite Test & Evaluation.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Arc reviewed UKAS schedule 7583 and Composite Test & Evaluation’s current home page on 30 September 2026. The guide retains the schedule’s exact Honiton-only testing statement, named composite and adhesive scope, test conditions and contact route. It does not infer capability outside the detailed schedule.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. Schedule of Accreditation 7583: Composite Test & Evaluation

    United Kingdom Accreditation Service · Reviewed

    UKAS schedule 7583, issue 008 dated 30 August 2024, identifies the Honiton laboratory, says testing is performed there only, and lists its detailed composite and structural-adhesive mechanical-testing scope. It does not establish booking, capacity, price, lead time or item acceptance.

  2. Composite Test & Evaluation home page

    Composite Test & Evaluation · Reviewed

    The current official home page identifies Composite Test & Evaluation as supporting non-metallic material testing requirements and publishes its Honiton contact address. The detailed accredited scope is taken from the UKAS schedule.