Skip to content

Fastener Testing Services Wolverhampton Laboratory

Fastener Testing ServicesWolverhampton

UKAS Schedule 24451, issue 009 dated 13 January 2026, identifies Fastener Testing Services at Units 53 and 60, IMEX Trading Estate, Upper Villiers Street, Wolverhampton, WV2 4XA, with testing performed at that address only. The schedule lists defined hardness, impact, tensile, fastener, metallurgical and elemental-analysis entries for metals, alloys and metal products.

Reviewed by Arc · About this review

Key facts

Current UKAS-listed Wolverhampton testing site
UKAS Schedule 24451, issue 009 dated 13 January 2026, identifies Fastener Testing Services at Units 53 and 60, IMEX Trading Estate, Upper Villiers Street, Wolverhampton, WV2 4XA, and says testing is performed at that address only.
Defined metals and fastener testing entries
The detailed schedule lists defined hardness, impact, tensile, fastener, metallurgical and elemental-analysis entries for metals, alloys and metal products.

Testing capabilities

Published hardness-testing entries

UKAS Schedule 24451 lists Vickers, micro Vickers, Brinell and Rockwell hardness entries for metals, alloys and metal products.

Published mechanical and fastener testing entries

UKAS Schedule 24451 lists Charpy impact, ambient-temperature tensile, proof-load testing for nuts, full-size fastener testing and wedge testing entries for specified metals, alloys and metal products.

Published metallurgical and chemical testing entries

UKAS Schedule 24451 lists defined decarburisation, grain-size, banding, inclusion-count, macro/micro-examination and elemental-analysis entries for carbon and low-alloy steels.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
Selected published mechanical-test limitsUKAS Schedule 24451 lists Charpy impact at −101 °C to ambient and −196 °C, including percentage shear and lateral expansion, and ambient-temperature tensile forces from 2.5 kN to 600 kN.These are selected current schedule limits for specified entries. They are not a complete facility-equipment inventory or universal capacity statement. Exact product, specimen, force, temperature, method, standard, conditions and exclusions remain those in the current UKAS schedule and require direct confirmation.

Access and contact

UKAS Schedule 24451 publishes Units 53 and 60, IMEX Trading Estate, Upper Villiers Street, Wolverhampton, WV2 4XA; +44 (0)7715 569730; and gary@fasttest.uk. Treat these as information routes and confirm the applicable scope, product, specimen, configuration, reporting, availability, price and lead time directly with Fastener Testing Services.

Facility contact

Address
Units 53 and 60, IMEX Trading Estate, Upper Villiers Street
Wolverhampton, WV2 4XA
United Kingdom

Standards and accreditation

UKAS Schedule 24451, ISO/IEC 17025:2017
UKAS Schedule 24451, issue 009 dated 13 January 2026, states ISO/IEC 17025:2017 accreditation for Fastener Testing Services, with testing performed at the Wolverhampton address only. The schedule lists the precise products, tests, methods and limits; confirm the applicable current scope directly.

What to confirm with the facility

  • Confirm the exact current scope, product, test and standard edition, specimen configuration, force and temperature, method, reporting, availability, price and lead time directly with Fastener Testing Services.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Arc reviewed Fastener Testing Services’ current company page and UKAS Schedule 24451, issue 009 dated 13 January 2026. The company page supplies provider-published context; the schedule supplies the independent site-only accreditation statement, information route and defined listed entries. The current provider page publishes commercial telephone/email routes that differ from the schedule’s named contact route; the guide presents the schedule’s route and records the distinction. Confirm the exact current scope, test configuration and terms directly with Fastener Testing Services.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. FTS Ltd. | Wolverhampton

    Fastener Testing Services · Reviewed

    Fastener Testing Services’ current page is used for provider-published context only. It does not establish the independent detailed UKAS scope, booking, availability, capacity, price, lead time or acceptance of a particular programme.

  2. UKAS Schedule 24451: Fastener Testing Services

    United Kingdom Accreditation Service · Reviewed

    UKAS Schedule 24451, issue 009 dated 13 January 2026, is used for Fastener Testing Services’s ISO/IEC 17025:2017 statement, Wolverhampton site-only testing statement, information route and defined metals/alloys/metal-products mechanical, metallurgical and chemical entries. The guide does not generalise the schedule beyond its listed products, tests, standards, methods, conditions, exclusions or limits.