Fluoro-TechWolverhampton

UKAS Schedule 10740 identifies Fluoro-Tech at Unit 3, Webnor Industrial Estate, Ettingshall, Wolverhampton, and lists defined non-destructive testing and Rockwell-hardness entries for metals, alloys and metal products. The schedule assigns laboratory NDT to location A and separately records limited NDT at customers’ premises as location B.

Reviewed by Arc · About this review

Key facts

UKAS-listed Wolverhampton laboratory and separate customer-premises activity
UKAS Schedule 10740 identifies Fluoro-Tech at Unit 3, Webnor Industrial Estate, Ettingshall, Wolverhampton, WV2 2LD, with NDT at laboratory location A. The schedule separately records NDT at customers’ premises as location B.
Defined current UKAS scope
UKAS Schedule 10740 lists defined magnetic-particle, dye-penetrant, ultrasonic, visual and Rockwell-hardness entries for specified metals, alloys, fasteners and metal products, subject to its stated location codes, products, methods, standards and conditions.

Testing capabilities

Defined fluorescent magnetic-particle and dye-penetrant entries at location A

The schedule lists fluorescent magnetic-particle testing for part-machined and fully machined fasteners, and fluorescent water-washable dye-penetrant testing for part-machined or fully machined fasteners, at laboratory location A.

Defined manual-contact ultrasonic entry at locations A and B

The schedule lists manual-contact ultrasonic testing for wrought and round bar, billet, forgings and part-machined fasteners at location A and separately at customer-premises location B.

Defined visual and Rockwell-hardness entries at location A

The schedule lists visual testing for specified fastener components and round barstock at location A, and Rockwell hardness (HRBW and HRC) for metals, alloys and metal products at location A.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
Selected fluorescent magnetic-particle conditionUp to 2000 A for part-machined and fully machined fasteners (bolts, nuts and washers) at location AThis is a selected current UKAS Schedule 10740 condition for a defined product and location-A entry. It is not a complete equipment inventory or universal capacity statement. Confirm the exact product, location, test method, standard, configuration, availability and terms directly with Fluoro-Tech.

Access and contact

UKAS Schedule 10740 lists Unit 3, Webnor Industrial Estate, Ettingshall, Wolverhampton, WV2 2LD, Mr Ian Evans, +44 (0)1902 219 899 and Ian.Evans@fluoro-tech.co.uk. Treat these as information routes and confirm the applicable location, product, scope, method, availability, price and lead time directly with Fluoro-Tech.

Facility contact

Address
Unit 3, Webnor Industrial Estate, Ettingshall
Wolverhampton, WV2 2LD

Standards and accreditation

UKAS Schedule 10740 — ISO/IEC 17025:2017
UKAS Schedule 10740, issue 012 dated 11 May 2026, states ISO/IEC 17025:2017 accreditation for its defined listed entries. Its Flexible Scope is limited to modifications of existing methods and newly revised, technically equivalent methods that introduce no new measurement principles and remain within the schedule’s parametric boundaries.

What to confirm with the facility

  • Confirm the exact current location-A or location-B applicability, product, test, method, standard, conditions, exclusions, Flexible Scope applicability, reporting, availability, price and lead time directly with Fluoro-Tech.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Arc reviewed UKAS Schedule 10740, issue 012 dated 11 May 2026. It identifies Fluoro-Tech’s Unit 3 Wolverhampton laboratory as location A and separately records customer-premises NDT as location B. The guide confines accreditation and capability claims to the schedule’s listed location codes, products, tests, standards, methods, conditions and Flexible Scope limits. Confirm the exact current scope, location and terms directly with Fluoro-Tech.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. Fluoro-Tech — UKAS Schedule 10740

    United Kingdom Accreditation Service · Reviewed

    UKAS Schedule 10740 is used for Fluoro-Tech’s identity, Wolverhampton location-A and separate customer-premises location-B NDT allocation, information route, ISO/IEC 17025:2017 statement, Flexible Scope conditions, and defined NDT and Rockwell-hardness entries. It does not establish scope beyond the listed location codes, products, tests, standards, methods, conditions, exclusions or limits, or booking, availability, capacity, price, lead time or acceptance of a particular programme.