Skip to content

Geotechnical Engineering Gloucester Geotechnical Laboratory

Geotechnical EngineeringGloucester, Gloucestershire

UKAS Schedule 2718, issue 023 dated 10 March 2026, identifies Geotechnical Engineering’s laboratory at Centurion House, Olympus Park, Quedgeley, Gloucester, GL2 4NF, and states that testing is performed at that address only. The schedule lists defined rock strength and soil laboratory entries, including soil physical properties, oedometer, triaxial, direct-shear, permeability, plasticity, compaction, CBR and specified shear-strength tests. The provider’s current laboratory page says chemical testing is subcontracted to UKAS/MCERTS-accredited laboratories, so this guide does not present chemical testing as an in-house Gloucester schedule entry.

Reviewed by Arc · About this review

Key facts

Current UKAS-listed Gloucester testing site
UKAS Schedule 2718, issue 023 dated 10 March 2026, identifies Geotechnical Engineering at Centurion House, Olympus Park, Quedgeley, Gloucester, GL2 4NF, and states that testing is performed at that address only.
Published enquiry route
Geotechnical Engineering’s current contact page publishes 01452 527 743 and geotech@geoeng.co.uk, alongside the Gloucester address.

Testing capabilities

Current UKAS-listed rock and soil testing entries

UKAS Schedule 2718 lists rock unconfined-compressive-strength and point-load-strength/anisotropy entries, plus defined laboratory soil water-content, density, particle-density, particle-size, incremental-oedometer, triaxial, direct-shear, flexible-wall-permeability, liquid-limit, plastic-limit, plasticity-index, compaction, CBR and specified shear-strength entries.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
Selected current UKAS Schedule 2718 methodsThe schedule lists BS EN ISO 17892-1:2014+A1:2022 for soil water content; BS EN ISO 17892-2:2014 for bulk density; BS EN ISO 17892-4:2016 for particle-size distribution; BS EN ISO 17892-5:2017 for incremental loading oedometer; BS EN ISO 17892-8:2018 and -9:2018 for defined triaxial tests; BS EN ISO 17892-10:2018 for direct shear; BS EN ISO 17892-11:2019 for flexible-wall permeability; BS EN ISO 17892-12:2018+A2:2022 for liquid limit, plastic limit and plasticity index; and BS 1377-2:2022 for stated compaction and CBR entries.This is a selected summary of the defined current Schedule 2718 entries, not a complete facility-equipment inventory or a general capability statement. Confirm the exact current material, test, standard, method, condition, range, reporting, availability and terms directly with Geotechnical Engineering.

Access and contact

Geotechnical Engineering’s current contact page lists 01452 527 743 and geotech@geoeng.co.uk, with the Gloucester address. Treat these as information routes and confirm applicable scope, sample requirements, reporting, availability, price and lead time directly with Geotechnical Engineering.

Facility contact

Address
Centurion House, Olympus Park, Quedgeley
Gloucester, Gloucestershire, GL2 4NF
United Kingdom

Standards and accreditation

UKAS Schedule 2718, ISO/IEC 17025:2017
UKAS Schedule 2718, issue 023 dated 10 March 2026, states that Geotechnical Engineering is accredited to ISO/IEC 17025:2017 for testing performed at the listed Gloucester address only. It lists defined rock and soil entries under stated methods. Use the schedule for the precise current scope and confirm the applicable entry directly with Geotechnical Engineering.

What to confirm with the facility

  • The provider says chemical testing is subcontracted to UKAS/MCERTS-accredited laboratories. This guide does not attribute chemical testing to the Gloucester laboratory’s in-house UKAS Schedule 2718 scope.
  • Confirm the exact current material, test, method, standard and edition, sample requirements, condition, range, reporting, availability, price and lead time directly with Geotechnical Engineering.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Arc reviewed Geotechnical Engineering’s current laboratory and contact pages and UKAS Schedule 2718, issue 023 dated 10 March 2026. The schedule supplies the exact Gloucester site, ISO/IEC 17025:2017 statement and defined rock and soil entries. The provider page says chemical testing is subcontracted to UKAS/MCERTS-accredited laboratories, so it is excluded from the in-house schedule description. Confirm the exact current scope, sample requirements and terms directly with Geotechnical Engineering.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. Laboratory Testing | Geotechnical

    Geotechnical Engineering · Reviewed

    Geotechnical Engineering’s current first-party laboratory page is used for published service context and its stated chemical-testing subcontracting boundary. Detailed in-house accreditation scope is confined to current UKAS Schedule 2718.

  2. Contact Us | Geotechnical

    Geotechnical Engineering · Reviewed

    Geotechnical Engineering’s current contact page is used for the published Gloucester address and enquiry routes. It does not establish booking, availability, capacity, price, lead time or acceptance of a particular programme.

  3. UKAS Schedule 2718: Geotechnical Engineering

    United Kingdom Accreditation Service · Reviewed

    UKAS Schedule 2718, issue 023 dated 10 March 2026, is used for the Gloucester location, ISO/IEC 17025:2017 statement and defined rock and soil testing entries. The guide does not generalise the schedule beyond its listed activities, methods, conditions and limits.