UKAS Schedule 1365, issue 030 dated 7 July 2026, identifies Geotechnics’s laboratory at The Geotechnical Centre, 203 Torrington Avenue, Tile Hill, Coventry, CV4 9AP, and states that testing is performed at that address only. The schedule lists defined aggregate, rock, soil and hydraulically bound/stabilized-material entries. Geotechnics’ current page says environmental, contamination and waste analysis is undertaken at an approved UKAS-accredited environmental laboratory, so this guide does not present that work as an in-house Coventry Schedule 1365 entry.

Reviewed by Arc · About this review

Key facts

Current UKAS-listed Coventry testing site
UKAS Schedule 1365, issue 030 dated 7 July 2026, identifies Geotechnics at The Geotechnical Centre, 203 Torrington Avenue, Tile Hill, Coventry, CV4 9AP, and states that testing is performed at that address only.
Published enquiry route
Geotechnics’ current contact page publishes mail@geotechnics.co.uk and 024 7669 4664 alongside its Coventry address.

Testing capabilities

Current UKAS-listed aggregate, rock, soil and material testing entries

UKAS Schedule 1365 lists aggregate water content; rock point-load strength/anisotropy and water content; defined laboratory soil water-content, density, particle-density, particle-size, oedometer, unconfined-compression, triaxial, direct-shear, liquid-limit, plasticity, compaction, MCV, CCV, CBR and stated shear-strength entries; and initial consumption of lime for hydraulically bound and stabilized civil-engineering materials.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
Selected current UKAS Schedule 1365 methodsThe schedule lists BS EN 1097-5:2008 for aggregate water content; BS EN ISO 17892-1:2014 through -5:2017 for specified soil water-content, density, particle-density, particle-size and oedometer entries; BS EN ISO 17892-7:2018, -8:2018 and -10:2018 for defined strength tests; BS EN ISO 17892-12:2018 for stated liquid-limit and plasticity entries; BS 1377-2:2022 for stated compaction, MCV, CCV and CBR entries; BS 1377-7:1990 for the listed shear-strength entry; and BS 1924-2:2018 for initial consumption of lime.This is a selected summary of the defined current Schedule 1365 entries, not a complete facility-equipment inventory or a general capability statement. Confirm the exact current material, test, standard, method, condition, range, reporting, availability and terms directly with Geotechnics.

Access and contact

Geotechnics’ current contact page lists mail@geotechnics.co.uk and 024 7669 4664, with the Coventry address. Treat these as information routes and confirm applicable scope, sample requirements, reporting, availability, price and lead time directly with Geotechnics.

Facility contact

Address
The Geotechnical Centre, 203 Torrington Avenue, Tile Hill
Coventry, West Midlands, CV4 9AP
United Kingdom

Standards and accreditation

UKAS Schedule 1365, ISO/IEC 17025:2017
UKAS Schedule 1365, issue 030 dated 7 July 2026, states that Geotechnics is accredited to ISO/IEC 17025:2017 for testing performed at the listed Coventry address only. It lists defined aggregate, rock, soil and hydraulically bound/stabilized-material entries under stated methods. Use the schedule for the precise current scope and confirm the applicable entry directly with Geotechnics.

What to confirm with the facility

  • The provider says environmental, contamination and waste analysis is undertaken at an approved UKAS-accredited environmental laboratory. This guide does not attribute that work to the Coventry laboratory’s in-house UKAS Schedule 1365 scope.
  • Confirm the exact current material, test, method, standard and edition, sample requirements, condition, range, reporting, availability, price and lead time directly with Geotechnics.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Arc reviewed Geotechnics’ current national-delivery and contact pages and UKAS Schedule 1365, issue 030 dated 7 July 2026. The schedule supplies the exact Coventry site, ISO/IEC 17025:2017 statement and defined aggregate, rock, soil and hydraulically bound/stabilized-material entries. The provider page says environmental, contamination and waste analysis is undertaken at an approved UKAS-accredited environmental laboratory, so it is excluded from the in-house schedule description. Confirm the exact current scope, sample requirements and terms directly with Geotechnics.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. One team. National delivery | Geotechnics

    Geotechnics · Reviewed

    Geotechnics’ current first-party page is used for published in-house laboratory context and its stated environmental-analysis boundary. Detailed in-house accreditation scope is confined to current UKAS Schedule 1365.

  2. Contact | Geotechnics

    Geotechnics · Reviewed

    Geotechnics’ current contact page is used for the published Coventry address and enquiry routes. It does not establish booking, availability, capacity, price, lead time or acceptance of a particular programme.

  3. UKAS Schedule 1365: Geotechnics

    United Kingdom Accreditation Service · Reviewed

    UKAS Schedule 1365, issue 030 dated 7 July 2026, is used for the Coventry location, ISO/IEC 17025:2017 statement and defined aggregate, rock, soil and hydraulically bound/stabilized-material entries. The guide does not generalise the schedule beyond its listed activities, methods, conditions and limits.