Skip to content

Glenair UK Mansfield Environmental and Electrical Test Laboratory

Glenair UKMansfield, Nottinghamshire

UKAS Schedule 29564, issue 003 dated 1 May 2026, identifies Glenair UK at 18 Hamilton Way, Mansfield, Nottinghamshire, NG18 5BU, and states that testing is performed at that address only. The schedule lists defined environmental, dynamic, electrical and metallic/oxide-coating-thickness entries for stated non-explosive electrical/electronic components, connectors and products.

Reviewed by Arc · About this review

Key facts

Current UKAS-listed Mansfield testing site
UKAS Schedule 29564, issue 003 dated 1 May 2026, identifies Glenair UK at 18 Hamilton Way, Mansfield, Nottinghamshire, NG18 5BU, and states that testing is performed at that address only.
Published enquiry route
Glenair’s current contact page publishes +44 (0) 1623 638 100 and sales@glenair.co.uk.

Testing capabilities

Current UKAS-listed environmental, dynamic, electrical and coating testing entries

UKAS Schedule 29564 lists defined climatic, thermal-shock, humidity, low-air-pressure and salt-mist entries; sinusoidal/random vibration and shock/bump entries; low-level/rated-current contact resistance, insulation resistance and dielectric-withstand-voltage entries; and metallic/oxide-coating-thickness testing. The listed materials include stated non-explosive electrical/electronic components, connectors and products, with a separate metallic-products coating-thickness entry.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
Selected current UKAS Schedule 29564 limits and methodsThe schedule lists stated temperature, humidity, vibration, shock/bump, electrical-resistance, insulation-resistance and dielectric-withstand-voltage ranges or limits, along with the listed IEC, EIA and ASTM methods. For example, it states 2–2650 Hz vibration ranges for listed sinusoidal and random entries, and 0.1–500 mΩ for listed low-level and rated-current contact-resistance entries.This is a selected summary of defined current Schedule 29564 entries, not a complete facility-equipment inventory or a general capability statement. Confirm the exact current product, test, standard and edition, method, technique, orientation, range, load, sample requirements, reporting, availability and terms directly with Glenair UK.

Access and contact

Glenair’s current contact page lists +44 (0) 1623 638 100 and sales@glenair.co.uk. Treat these as information routes and confirm applicable scope, sample requirements, reporting, availability, price and lead time directly with Glenair UK.

Facility contact

Address
18 Hamilton Way
Mansfield, Nottinghamshire, NG18 5BU
United Kingdom

Standards and accreditation

UKAS Schedule 29564, ISO/IEC 17025:2017
UKAS Schedule 29564, issue 003 dated 1 May 2026, states that Glenair UK is accredited to ISO/IEC 17025:2017 for testing performed at the listed Mansfield address only. It lists defined environmental, dynamic, electrical and metallic/oxide-coating-thickness entries under stated methods, conditions, ranges and limits. Use the schedule for the precise current scope and confirm the applicable entry directly with Glenair UK.

What to confirm with the facility

  • UKAS Schedule 29564 defines particular materials/products, properties, methods, conditions, equipment dimensions, ranges and limits. This guide does not generalise those entries into an unrestricted capability, availability or programme-acceptance claim.
  • Confirm the exact current product, test, method, standard and edition, technique, orientation, range, load, sample requirements, reporting, availability, price and lead time directly with Glenair UK.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Arc reviewed Glenair’s current contact page and UKAS Schedule 29564, issue 003 dated 1 May 2026. The schedule supplies the exact Mansfield site, ISO/IEC 17025:2017 statement and defined environmental, dynamic, electrical and coating-thickness entries. The guide confines technical and accreditation claims to those stated schedule entries. Confirm the exact current scope, sample requirements and terms directly with Glenair UK.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. Contact Us | Glenair

    Glenair UK · Reviewed

    Glenair’s current first-party contact page is used for published telephone and email information routes. It does not establish detailed current UKAS scope, booking, availability, capacity, price, lead time or acceptance of a particular programme.

  2. UKAS Schedule 29564: Glenair UK

    United Kingdom Accreditation Service · Reviewed

    UKAS Schedule 29564, issue 003 dated 1 May 2026, is used for the Mansfield location, ISO/IEC 17025:2017 statement and defined environmental, dynamic, electrical and coating-thickness entries. The guide does not generalise the schedule beyond its listed activities, methods, conditions, ranges and limits.