UKAS Schedule 29564, issue 003 dated 1 May 2026, identifies Glenair UK at 18 Hamilton Way, Mansfield, Nottinghamshire, NG18 5BU, and states that testing is performed at that address only. The schedule lists defined environmental, dynamic, electrical and metallic/oxide-coating-thickness entries for stated non-explosive electrical/electronic components, connectors and products.
Reviewed by Arc · About this review
Key facts
- Current UKAS-listed Mansfield testing site
- UKAS Schedule 29564, issue 003 dated 1 May 2026, identifies Glenair UK at 18 Hamilton Way, Mansfield, Nottinghamshire, NG18 5BU, and states that testing is performed at that address only.
- Published enquiry route
- Glenair’s current contact page publishes +44 (0) 1623 638 100 and sales@glenair.co.uk.
Testing capabilities
Current UKAS-listed environmental, dynamic, electrical and coating testing entries
UKAS Schedule 29564 lists defined climatic, thermal-shock, humidity, low-air-pressure and salt-mist entries; sinusoidal/random vibration and shock/bump entries; low-level/rated-current contact resistance, insulation resistance and dielectric-withstand-voltage entries; and metallic/oxide-coating-thickness testing. The listed materials include stated non-explosive electrical/electronic components, connectors and products, with a separate metallic-products coating-thickness entry.
Equipment and published limits
| Specification | Published value | Conditions |
|---|---|---|
| Selected current UKAS Schedule 29564 limits and methods | The schedule lists stated temperature, humidity, vibration, shock/bump, electrical-resistance, insulation-resistance and dielectric-withstand-voltage ranges or limits, along with the listed IEC, EIA and ASTM methods. For example, it states 2–2650 Hz vibration ranges for listed sinusoidal and random entries, and 0.1–500 mΩ for listed low-level and rated-current contact-resistance entries. | This is a selected summary of defined current Schedule 29564 entries, not a complete facility-equipment inventory or a general capability statement. Confirm the exact current product, test, standard and edition, method, technique, orientation, range, load, sample requirements, reporting, availability and terms directly with Glenair UK. |
Access and contact
Glenair’s current contact page lists +44 (0) 1623 638 100 and sales@glenair.co.uk. Treat these as information routes and confirm applicable scope, sample requirements, reporting, availability, price and lead time directly with Glenair UK.
Facility contact
- Address
- 18 Hamilton Way
Mansfield, Nottinghamshire, NG18 5BU
United Kingdom - sales@glenair.co.uk
- Telephone
- +44 (0)1623 638 100
- Website
- Official test house website
Standards and accreditation
- UKAS Schedule 29564, ISO/IEC 17025:2017
- UKAS Schedule 29564, issue 003 dated 1 May 2026, states that Glenair UK is accredited to ISO/IEC 17025:2017 for testing performed at the listed Mansfield address only. It lists defined environmental, dynamic, electrical and metallic/oxide-coating-thickness entries under stated methods, conditions, ranges and limits. Use the schedule for the precise current scope and confirm the applicable entry directly with Glenair UK.
What to confirm with the facility
- UKAS Schedule 29564 defines particular materials/products, properties, methods, conditions, equipment dimensions, ranges and limits. This guide does not generalise those entries into an unrestricted capability, availability or programme-acceptance claim.
- Confirm the exact current product, test, method, standard and edition, technique, orientation, range, load, sample requirements, reporting, availability, price and lead time directly with Glenair UK.
Before requesting a test
Public information not available. Contact test facility provider for more information.
Frequently asked questions
Public information not available. Contact test facility provider for more information.
Related testing facilities
Public information not available. Contact test facility provider for more information.
Further reading
Public information not available. Contact test facility provider for more information.
Sources and review
Arc reviewed Glenair’s current contact page and UKAS Schedule 29564, issue 003 dated 1 May 2026. The schedule supplies the exact Mansfield site, ISO/IEC 17025:2017 statement and defined environmental, dynamic, electrical and coating-thickness entries. The guide confines technical and accreditation claims to those stated schedule entries. Confirm the exact current scope, sample requirements and terms directly with Glenair UK.
Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.
Glenair’s current first-party contact page is used for published telephone and email information routes. It does not establish detailed current UKAS scope, booking, availability, capacity, price, lead time or acceptance of a particular programme.
UKAS Schedule 29564: Glenair UK
UKAS Schedule 29564, issue 003 dated 1 May 2026, is used for the Mansfield location, ISO/IEC 17025:2017 statement and defined environmental, dynamic, electrical and coating-thickness entries. The guide does not generalise the schedule beyond its listed activities, methods, conditions, ranges and limits.