Skip to content

Minton, Treharne and Davies

Minton, Treharne and DaviesCardiff

Minton, Treharne and Davies operates a Cardiff laboratory at Forest Farm Industrial Estate, Longwood Drive, Coryton, Cardiff, CF14 7HY. The current contact page publishes +44 (0)2920 540 000 and an enquiry form. UKAS schedule 0077, issue 088 dated 02 September 2026, assigns Cardiff location code A and selected customer-site activities code B. This guide selects materials and NDT methods from pages 1 to 4 of the larger 18-page schedule. Confirm the required method, location, current controlled scope and sample arrangements directly.

Reviewed by Arc · About this review

Key facts

Cardiff laboratory
The current contact page publishes Forest Farm Industrial Estate, Longwood Drive, Coryton, Cardiff, CF14 7HY, United Kingdom. The dated schedule identifies Longwood Drive, Forest Farm, Cardiff, Wales, CF14 7HY as location A.
Current information route
Use +44 (0)2920 540 000 or the official enquiry form to discuss materials testing and engineering services.
Separate location allocations
Cardiff is location A. Suitable customer premises for the listed permanent-joining inspection and NDT activities are code B. Leeds, code C, is separately allocated wastewater microbiological testing. This guide does not transfer those Leeds tests to Cardiff.

Testing capabilities

Cardiff ambient tensile testing

At location A, the dated scope lists tensile testing at ambient temperature with forces up to 500 kN, using BS EN ISO 6892-1 Method B and ASTM A370. The row does not print method editions or a lower force limit. Confirm the applicable controlled method.

Cardiff Vickers hardness testing

The location A entry lists Vickers hardness under the HV10 condition to BS EN ISO 6507-1. No other hardness scale or unprinted standard edition is inferred.

Cardiff Charpy V-notch impact testing

At location A, Charpy V-notch impact testing is listed at -196°C and separately from -80°C to ambient under BS EN ISO 148-1. These conditions do not establish a continuous range from -196°C to ambient.

Cardiff weldment examination to specified codes

The location A weldment entry covers bend, fracture, hardness, tensile, Charpy and macro examination in accordance with specified welding codes. References include BS 4872-1 and -2, BS EN ISO 9606-1 and -2, BS EN ISO 15614-1 and -2, BS EN ISO 17639 and ASME IX. Confirm the required code and edition. This is not unrestricted welding certification.

Cardiff stainless-steel pitting corrosion

At location A, stainless-steel pitting-corrosion testing is listed to ASTM G48 Method A. The material and method boundary is retained. Confirm the applicable controlled edition and test condition.

Ultrasonic and phased-array testing at A and B

Ultrasonic flaw detection and thickness measurement are listed at A and B for the stated light and dense metals and alloys, castings, weldments, forgings, components, structures and composite materials. References include BS EN ISO 17635, BS EN ISO 17640, ISO 16809:2019, ISO 16810:2014 and ASME V Articles 4 and 5. Phased-array ultrasonic testing is separately listed to BS EN ISO 13588.

Liquid penetrant inspection at A and B

Colour-contrast and fluorescent liquid penetrant inspection is listed at A and B to BS EN ISO 3452-1, ASME V Article 6 and RRP 58003. The schedule lists fixed penetrant-line and portable equipment. Confirm the required inspection and location.

Radiography at A and B

The radiography entries at A and B list X-rays at no more than 450 kV and gamma rays using iridium-192 below 27 Ci. References are BS EN ISO 17636-1, ASME V Article 2 and RRP 58006. These are source or equipment conditions, not specimen-dimension limits.

Magnetic particle inspection at A and B

For ferromagnetic materials, the A and B entry lists inspection using permanent and electrically induced magnetism under BS EN ISO 17638, BS EN ISO 9934 Part 1 and ASME V Article 7. Confirm the material and required inspection technique.

Weld eddy-current and visual examination at A and B

For weldments only, eddy-current testing by complex-plane analysis using portable flaw detectors is listed at A and B under BS EN ISO 15549, ISO 17643:2015 and ASME V Article 8. Visual examination of welds is listed under BS EN 13018, BS EN ISO 17637 and ASME V Article 9 at A and B.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
Cardiff tensile conditionAmbient temperature, forces up to 500 kNLocation A, BS EN ISO 6892-1 Method B and ASTM A370. No lower force limit or specimen-size rating is published in this row.
Cardiff Charpy temperature conditions-196°C and -80°C to ambientTwo separate conditions at A under BS EN ISO 148-1. No continuous range between -196°C and -80°C is inferred.
Cardiff Vickers conditionHV10Location A, BS EN ISO 6507-1. This does not establish other hardness scales or a machine-capacity rating.
Radiography source conditions at A and BX-ray ≤450 kV, iridium-192 <27 CiMethod-specific source or equipment conditions. Confirm the technique, location and inspected article directly.

Access and contact

Contact the Cardiff office on +44 (0)2920 540 000 or use the official enquiry form. Specify the material, method, laboratory A or eligible customer-site B activity, current scope and sample requirements. Confirm the arrangements before sending material or planning site work.

Facility contact

Address
Forest Farm Industrial Estate, Longwood Drive, Coryton
Cardiff, CF14 7HY
United Kingdom

Standards and accreditation

UKAS 0077 and ISO/IEC 17025:2017
The direct schedule names Minton, Treharne and Davies, issue 088 dated 02 September 2026, accredited to ISO/IEC 17025:2017 for the listed tests and location codes. This guide selects materials and NDT entries from pages 1 to 4. Separate live accreditation status was not verified.
QP19 flexible-scope conditions
The selected mechanical and NDT scope allows new versions of existing accredited standard methods and technically equivalent standard methods to be introduced under documented in-house procedure QP19. Confirm the current controlled method and edition. Unprinted editions and unrelated new methods are not inferred.

What to confirm with the facility

  • The selected mechanical, weldment and stainless-steel corrosion entries are allocated to Cardiff A. The selected NDT entries identify A and B. These allocations do not establish that every laboratory test is available at customer premises or Leeds.
  • This guide selects materials and NDT methods from the larger schedule. Location A also has other listed test areas, while location C identifies Leeds wastewater microbiology. Confirm any unlisted requirement and its exact laboratory and scope directly.
  • Confirm sample quantity, dimensions and preparation, current accreditation scope, quotation, turnaround time and reporting requirements directly.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Reviewed by Arc on 1 October 2026 using fresh official homepage, contact and mechanical-testing pages and the direct UKAS 0077 PDF. All 18 pages were extracted. Pages 1 to 4 were visually checked for this materials and NDT selection. Their printed issue date is 02 September 2026. Location codes, method conditions and QP19 scope qualifications are retained. Separate live accreditation status was not verified.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. Minton Treharne & Davies - Scientific Consultancy, Surveying, Analysis & Testing

    Minton, Treharne and Davies · Reviewed

    The homepage identifies the Cardiff laboratory and headquarters. Group offices, broad approvals and worldwide services are not treated as evidence that every test is available at Cardiff or customer sites.

  2. Contact Minton Treharne & Davies | Scientific Consultants & Surveyors

    Minton, Treharne and Davies · Reviewed

    The page publishes the Cardiff address, +44 (0)2920 540 000 and an enquiry form. Telephone and form are the information route used here. Other office contacts are not transferred to Cardiff.

  3. Mechanical Testing | Tensile, Impact and Hardness Testing | MTD Group

    Minton, Treharne and Davies · Reviewed

    The page describes mechanical testing and laboratory 0077, alongside broader microscopy services. This guide’s selected material and NDT methods follow pages 1 to 4 of the dated schedule.

  4. UKAS schedule 0077 - issue 088, 02 September 2026

    United Kingdom Accreditation Service · Reviewed

    The 18-page schedule covers several test areas and locations. This guide selects materials and NDT entries from pages 1 to 4. Cardiff A, customer-site B and Leeds C remain distinct. QP19 flexible-scope conditions are retained and unprinted method editions are not invented. Separate live-register status was not verified.