Skip to content

MS Testing Newton Aycliffe laboratory

MS Testing, a trading division of Mariner Systems (UK)Newton Aycliffe, County Durham

MS Testing is a trading division of Mariner Systems (UK) Ltd at 5 Maple Way, Aycliffe Industrial Park, Newton Aycliffe, County Durham, DL5 6BF. The current contact page publishes +44 (0) 1325 321366 and info@mstesting.co.uk. This guide selects environmental, dynamic, electrical and EMC entries from UKAS schedule 4413, issue 029 dated 11 December 2025. Laboratory tests use location A. IPX5 is also allocated to S at suitable off-site locations after contract review. Confirm the required method, current controlled scope and equipment arrangements.

Reviewed by Arc · About this review

Key facts

Newton Aycliffe laboratory
The current contact page identifies 5 Maple Way, Aycliffe Industrial Park, Newton Aycliffe, County Durham, DL5 6BF, United Kingdom. MS Testing is a division of Mariner Systems (UK) Ltd.
Information route and customer access
Use +44 (0) 1325 321366 or info@mstesting.co.uk. The homepage says customers can ship equipment for testing or accompany it to witness tests. Confirm the arrangements directly.
A and S location allocations
The dated schedule assigns EMC and environmental laboratory activities to A. Off-site activity S is limited to IPX5 testing at a suitable location and requires contract review between the laboratory and customer. The individual IPX5 row is marked A and S.
Equipment boundary
The environmental scope identifies non-explosive items for electrical installations in ships, control and instrumentation, and maritime navigation or radio communication equipment and systems. Confirm the required product and method coverage.

Testing capabilities

Temperature, humidity and salt-mist testing at A

The environmental scope lists constant or cyclic high and low temperature, high humidity and salt mist. Separate chamber conditions are tabulated below. Selected references include BS EN and IEC 60068-2-2:2007, BS EN and IEC 60068-2-1:2007, BS EN 60068-2-30:2005 Test Db and BS EN 60068-2-78:2013. Salt-mist references include EN 60068-2-52:Kb:1996 and :2017. Confirm the required profile and applicable listed edition.

Published thermal-shock entry

The scope lists Na shock, Nb cycle and Nc fluid bath under BS EN 60068-2-14:2009 and :2023, with limits of -30°C and +80°C and a maximum chamber size of 990 × 1080 × 1080 mm. This row does not print a location code, while the page header states the main address. Confirm the mode, location allocation and usable equipment dimensions.

Ingress-protection testing at A and conditional IPX5 at S

The schedule lists individual IP1X, IP2X, IP3X, IP4X, IP5X, IP6X, IPX4, IPX5, IPX6, IPX7 and IPX8 entries under BS EN 60529:1992 with A1, A2 and AC:2019 as printed. The listed entries are at A, with IPX5 additionally at S subject to site suitability and contract review. These symbols do not establish every possible combined IP rating.

Ambient vibration and half-sine shock at A

Sinusoidal and random vibration are separately listed at ambient temperature from 2 to 3000 Hz. The schedule prints maximum pk/pk displacement as ±25 mm for each entry. Confirm that convention and the required profile directly. Half-sine shock is listed at ambient temperature up to 50 gn with pulse widths from 6 to 11 ms. Selected references are BS EN 60068-2-6:2008, BS EN 60068-2-64:2019 and BS EN 60068-2-27:2009.

Inclination, acoustic noise and compass-safe distance at A

Static and dynamic inclination are separately listed with a maximum angle of 45°, item size of 3 × 3 × 3 m and mass of 500 kg. Acoustic noise measures sound pressure at 1 m from 30 to 135 dBA under BS EN 60945 section 11.1. Compass-safe distance is listed under IEC 60945:2002 + Corr 1:2008 section 11.2. Inclination limits do not establish vibration or shock payload ratings.

Voltage and power-supply tests at A

The scope lists high-voltage testing at 1500 V ac and an insulation-breakdown entry at 500 V dc and 100 MΩ, with specified tests before and after damp heat and low temperature. Power-supply variation and failure are listed under IEC 60945:2002 + Corr 1:2008 sections 10.7 and 10.8. Confirm the relevant method and electrical setup.

ESD, transient, surge and voltage-dip tests at A

ESD is listed at 8 kV air discharge and 6 kV contact discharge, including EN 61000-4-2:2025. Electrical fast-transient bursts and surge each list 4 kV, with references including EN 61000-4-4:2012 and EN 61000-4-5:2014 + A1:2017. Voltage dips and interruptions include EN IEC 61000-4-11:2020. Confirm the required listed standard and test condition.

Radiated and conducted immunity at A

Radiated immunity has separate entries for 80 to 6000 MHz at ≤10 V/m and 80 to 1000 MHz at 20 V/m with a uniform field size of 1.5 × 0.5 m. References include EN IEC 61000-4-3:2020. Conducted RF immunity covers 150 kHz to 230 MHz at RF voltage up to 10 V rms, including EN 61000-4-6:2023. Conducted low-frequency immunity covers 50 Hz to 10 kHz, including IACS E10:2024. These are separate method conditions.

EMC emissions measurements at A

The schedule lists conducted emissions from 9 kHz to 30 MHz, radiated emissions from 150 kHz to 6000 MHz, discontinuous emissions from 10 kHz to 30 MHz and power-absorbing emissions measurements from 30 to 300 MHz. Conducted current harmonics are measured up to the 40th harmonic for equipment input current ≤16 A per phase, and AC mains flicker is separately listed. Applicable product, port and basic-standard exclusions below must be retained.

Magnetic-field immunity at A

The power-frequency magnetic-field entry covers DC to 1 kHz at field strength up to 30 A/m, with EN 61000-4-8:2010 among its references. Pulsed magnetic-field immunity is separately listed up to 1000 A/m under references including EN 61000-4-9:2016.

Published needle-flame test entry

The schedule lists fire-hazard needle-flame testing to EN 60695-11-5:2017, with supporting tests covered in IEC 60092-101:2018 and IACS E10:2024. This row does not print a location code, while the page header states the main address. Confirm the required test and location allocation.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
High-temperature chamber entries+70°C with 1.6 × 1.9 × 1.6 m, +100°C with 0.8 × 0.8 × 0.8 m, +180°C with 1.2 × 1.0 × 1.2 mSeparate published maximum-temperature and maximum-chamber-size entries for constant/cyclic tests at A. Confirm the chosen chamber and usable test envelope.
Low-temperature chamber entries-25°C with 1.6 × 1.9 × 1.6 m, -40°C with 0.8 × 0.8 × 0.8 m, -60°C with 1.2 × 1.0 × 1.2 mSeparate published minimum-temperature and maximum-chamber-size entries for constant/cyclic tests at A. Do not combine them into one chamber rating.
High-humidity condition10% to 98% rh at temperatures >+10°C, maximum +70°CLocation A, maximum chamber size 1.6 × 1.9 × 1.6 m. The humidity and temperature conditions are not a guarantee that every endpoint can be achieved together.
Salt-mist temperatureAmbient to +55°CLocation A, listed salt-mist methods and editions. Confirm the required exposure profile.
Thermal-shock limits-30°C to +80°C, maximum chamber size 990 × 1080 × 1080 mmPublished Na/Nb/Nc entry. Its location-code cell is blank. Confirm mode, allocation and usable dimensions.
Sinusoidal and random vibration2 to 3000 Hz at ambient, maximum pk/pk displacement printed as ±25 mmSeparate entries at A. The displacement convention is retained as printed. No force, acceleration or payload rating is inferred.
Half-sine shockMaximum 50 gn, pulse width 6 to 11 ms, ambient temperatureLocation A. Confirm the required pulse and equipment configuration.
Static and dynamic inclinationMaximum 45°, item size 3 × 3 × 3 m, mass 500 kgSeparate entries at A. These limits do not apply to vibration or shock and do not guarantee simultaneous use of all maxima.
Radiated-immunity conditions80 to 6000 MHz at ≤10 V/m, separately 80 to 1000 MHz at 20 V/mLocation A. The second condition states a uniform field size of 1.5 × 0.5 m. These are distinct frequency and field conditions.
Conducted RF immunity150 kHz to 230 MHz, RF voltage up to 10 V rmsLocation A. Confirm the applicable method, port and setup.
ESD, burst and surge conditionsESD 8 kV air and 6 kV contact, bursts 4 kV, surge 4 kVSeparate EMC entries at A. Confirm the required method and level.
Magnetic-immunity conditionsDC to 1 kHz up to 30 A/m, separately pulsed up to 1000 A/mSeparate location A method conditions. No common frequency range for the pulsed entry is inferred.

Access and contact

Contact +44 (0) 1325 321366 or info@mstesting.co.uk to discuss the required test, equipment and current scope. The homepage describes shipment for testing and customer attendance to witness tests. Confirm preparation, shipping and attendance arrangements directly. Off-site IPX5 at S requires a suitable location and contract review.

Facility contact

Address
5 Maple Way, Aycliffe Industrial Park
Newton Aycliffe, County Durham, DL5 6BF
United Kingdom

Standards and accreditation

UKAS 4413 and ISO/IEC 17025:2017
The direct ten-page schedule names MS Testing as a trading division of Mariner Systems (UK) Ltd, issue 029 dated 11 December 2025, accredited to ISO/IEC 17025:2017 for the listed scope. Laboratory A and conditional off-site IPX5 at S are kept distinct. Separate live accreditation status was not verified.
Marine testing context and listed method editions
The homepage describes marine type-approval testing to IACS E10, EN60945 and class-society rules. The dated scope lists IACS E10:2022 and :2024 for relevant entries. Published website method editions and the direct schedule are separate sources. Confirm the required controlled edition and any approval process. Testing does not itself establish authority to grant a class approval.
EMC product-standard restriction
The schedule states that listed EMC product standards are accredited only to the extent that they call up the basic standards accredited within this schedule. Confirm every required basic method and the applicable product exclusions.

What to confirm with the facility

  • The schedule repeats a main-address-only header, but its location table expressly allocates off-site environmental IPX5 testing to S, subject to suitability and contract review. The IPX5 method row is marked A and S. No wider off-site test service is inferred.
  • Conducted-emissions EN 55022:2006 + A1:2007 excludes telecommunication ports, and EN 55032:2015 + A11:2020 excludes the antenna port. The listed EN 55011 conducted entry excludes Group 2 apparatus and grid-connected power converters. Listed EN 55011 radiated-emissions entries exclude Group 2 apparatus. Confirm the exact applicable product-standard entry.
  • This is a selection from the ten-page schedule. Each chamber, frequency, field, voltage, pulse, inclination or mass condition belongs to its own entry. The thermal-shock and needle-flame rows do not print location codes. Confirm the required method, allocation and combination of conditions.
  • Confirm equipment quantity, dimensions and mass, fixtures, operating modes, preparation, quotation, turnaround time, reporting and attendance or shipment arrangements directly.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Reviewed by Arc on 1 October 2026 using fresh official homepage, contact and laboratory-facilities pages and the direct UKAS 4413 PDF. All ten pages were extracted and visually checked. The printed issue date is 11 December 2025. Location allocations, separate method conditions, blank location-code cells and EMC exclusions are retained. Separate live accreditation status was not verified.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. MS Testing - EMC, Environmental and Marine Type Approval Testing Specialists

    MS Testing, a division of Mariner Systems (UK) Ltd · Reviewed

    The homepage identifies the Newton Aycliffe laboratory and operator division, published customer access and chamber or vibration equipment. Broad marine approval statements do not establish certification authority.

  2. Contact Details

    MS Testing, a division of Mariner Systems (UK) Ltd · Reviewed

    The page publishes the exact laboratory address, +44 (0) 1325 321366 and info@mstesting.co.uk. This guide uses the general office route. A conflicting fax number is omitted.

  3. Laboratory Facilities

    MS Testing, a division of Mariner Systems (UK) Ltd · Reviewed

    The page lists EMC and environmental tests with printed method editions. The direct dated UKAS schedule supplies the scope and numeric conditions used here.

  4. UKAS schedule 4413, issue 029, 11 December 2025

    United Kingdom Accreditation Service · Reviewed

    All ten pages were extracted and visually checked. Laboratory A and the conditional off-site IPX5 activity S are distinguished. Chamber limits, test conditions, exclusions and blank location-code cells remain qualified.