NDT Services, Unit 10A Derby laboratory

NDT ServicesDerby, Derbyshire

NDT Services’s Unit 10A laboratory in Derby is listed by UKAS under Testing Laboratories 0084. The current linked schedule assigns this address location code A and lists eddy-current, liquid-penetrant, radiographic, ultrasonic and magnetic-particle inspection methods. This guide follows those site A rows. The separate Unit 5 laboratory’s tensile and mechanical ranges, and Intertek’s global catalogue, are not treated as Unit 10A services. Contact the named local route to agree the material, method, acceptance criteria and report.

Reviewed by Arc · About this review

Key facts

Current legal identity and site
The official UKAS result lists NDT Services at Unit 10A, Victory Park, Victory Road, Derby, Derbyshire, DE24 8ZF. The schedule identifies this laboratory as location A.
Specific NDT methods
The detailed schedule rows include eddy current, penetrant, radiography, ultrasonic flaw detection and magnetic-particle inspection at location A, subject to the stated materials, methods and standards.
Accreditation evidence
UKAS lists Testing Laboratories 0084 and links issue 058 of the ISO/IEC 17025:2017 schedule, dated 18 November 2025. Accreditation applies to the stated activities and location codes.
Named local enquiry
The schedule names Ms Sandra Evans and gives Sandra.Evans@intertek.com and +44 1332 275700. Confirm the correct laboratory, service and arrangements before sending specimens or requesting work.

Testing capabilities

Eddy-current flaw detection

Site A’s schedule lists manual and automatic scanning for light and dense metals and alloys, including castings, forgings and weldments. Agree the material, geometry, inspection technique and applicable acceptance criteria.

Liquid-penetrant inspection

The schedule lists manual colour-contrast application and a fluorescent immersion line explicitly at Site A. The row covers the stated light and dense metals and alloys. Confirm the component, preparation and procedure for the proposed inspection.

Radiographic inspection

Location A has X-ray radiography and digital-detector X-ray rows, plus gamma-ray radiography. The published X-ray energy range is 15 keV to 320 keV. Agree the material, geometry, technique and image/report requirements without treating source energy as a specimen-thickness guarantee.

Ultrasonic flaw detection

Automated examination and immersion methods are coded A. Manual contact inspection is coded A and C, with C meaning suitable customer premises. Confirm which method and location are appropriate rather than assuming all techniques apply everywhere.

Magnetic-particle inspection

For ferromagnetic metals, the A and C row lists black and fluorescent ink with universal and portable equipment, using AC and DC up to 3000 A. The separate 800 A current-flow row belongs to B and is not this site’s published rating.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
Site A X-ray energy15 keV to 320 keV for X-ray radiography and digital-detector X-ray inspectionPages 4 and 5 explicitly label these rows Site A. This is the published source-energy interval, with no specimen dimensions, thickness capability, resolution or complete inspection envelope inferred.
A and C magnetic-particle rowAC and DC up to 3000 A for black and fluorescent ink universal and portable equipmentPage 6 limits this row to ferromagnetic metals and location codes A and C. It is an equipment/method condition, not a load rating or blanket assurance for every component. The B 800 A row remains separate.

Access and contact

Contact Ms Sandra Evans at Sandra.Evans@intertek.com or +44 1332 275700 for the Unit 10A laboratory, Victory Park, Victory Road, Derby, Derbyshire DE24 8ZF. The UKAS result and schedule give this local route, with Intertek’s current page corroborating the phone. State the material, component geometry, method, applicable specification and required report. Ask the laboratory to confirm the delivery location, preparation, availability, quotation and exact accredited scope. Customer-premises work is a separate location C category and only its listed methods apply.

Facility contact

Address
Unit 10A, Victory Park, Victory Road
Derby, Derbyshire, DE24 8ZF
United Kingdom

Standards and accreditation

UKAS 0084 and ISO/IEC 17025:2017
The fresh official UKAS directory lists NDT Services under Testing Laboratories 0084. Its linked schedule is issue 058, dated 18 November 2025, accredited to ISO/IEC 17025:2017. Use the relevant material, method and location A rows rather than treating the certificate as accreditation for every activity or site.
Selected eddy-current and surface-inspection standards
The site A eddy-current row includes BS EN ISO 15549:2019. The penetrant row includes BS EN ISO 3452-1:2021, ASTM E165-23 and ASTM E1417-21, with the fluorescent immersion line expressly at A. The A and C magnetic-particle row includes BS EN ISO 9934-1:2016. These are selected schedule entries, with their individual methods and conditions to confirm.
Selected radiography and ultrasonic standards
The site A X-ray row includes BS EN ISO 17636-1:2022, while digital-detector X-ray uses BS EN ISO 17636-2:2022. The ultrasonic automated and manual-contact rows include BS EN ISO 17640:2018, and the immersion row includes AMS-STD-2154 Rev D. Confirm the required method, revision, material and location against the full schedule.

What to confirm with the facility

  • Unit 10A is A, while Unit 5, Victory House, 99 Victory Road, Derby DE24 8EL is B. The detailed tensile and other mechanical ranges coded B are not assigned to this guide’s Unit 10A facility. Broad activity headings do not establish every detailed test at both laboratories.
  • The schedule’s welding-code row is marked A,B* and states that NDT techniques are not specific to any site, with the laboratory to contact for details. It is not used to promise the full listed mechanical, metallurgical and NDT workflow independently at Unit 10A.
  • The Intertek page reached from the legacy domain describes services and credentials across the group. It also says accreditation has a defined legal-entity and site scope. Group approvals, personnel certification and worldwide techniques are not additional Unit 10A accreditation or service evidence.
  • Published X-ray energy and magnetic-particle current do not establish a common specimen size, thickness, sensitivity or guaranteed detection performance. Confirm the inspection procedure, component condition and acceptance criteria with the laboratory.
  • Agree specimen preparation, delivery, safety information, inspection coverage, witness requirements, report content, costs and programme before requesting work.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Reviewed by Arc on 1 October 2026 from a fresh official UKAS result, the linked seven-page schedule and the observed Intertek redirect. The schedule’s issue date is 18 November 2025, while PDF creation/modification metadata are 19 November 2025. UKAS directory-template publication on 30 June 2020 and modification on 11 November 2022 are not dates for this organisation result or scope update. Intertek publication dates were not verified. Unit 10A location A, Unit 5 location B and customer-premises location C remain distinct, with method and footnote conditions retained.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. UKAS NDT Services testing schedule 0084, issue 058

    United Kingdom Accreditation Service · Reviewed

    The seven-page schedule is issue 058, dated 18 November 2025. Unit 10A is location A, Unit 5 is B and suitable customer premises are C. Detailed site A NDT rows are used, with the A,B* welding-code footnote retained. PDF creation/modification metadata are dated 19 November 2025, separate from the issue date and this review.

  2. UKAS current NDT Services testing laboratory result

    United Kingdom Accreditation Service · Reviewed

    The result lists NDT Services under Testing Laboratories 0084 at Unit 10A and links this schedule. Its directory-template metadata records publication on 30 June 2020 and modification on 11 November 2022. Those template dates do not establish when this organisation result or scope was updated.

  3. Intertek NDT page reached from the NDT Services domain

    Intertek · Reviewed

    A fresh request to http://www.ndtservices.co.uk redirects here. The page states that Derby laboratory accreditations have defined legal-entity and site scopes and gives the matching phone. Its global services, company approvals and personnel credentials are not allocated to Unit 10A. No publication or modification date was verified.