Panasonic Manufacturing UK testing laboratories, Cardiff
Panasonic Manufacturing UKCardiff
Panasonic Manufacturing UK advertises customer testing laboratories at its Cardiff site. Selected current owner pages describe EMC immunity and emissions, climatic testing and vibration. The contact page lists Pentwyn Industrial Estate, Cardiff CF23 7XB and a dedicated testing enquiry route. Published measurements and platform sizes have specific meanings, with exact configurations and report status to confirm. The laboratory management-system statement does not verify current method accreditation.
Reviewed by Arc · About this review
Key facts
- Owner-listed site
- Panasonic Manufacturing UK, Pentwyn Industrial Estate, Cardiff CF23 7XB, United Kingdom. No additional street or coordinates are verified.
- Selected customer services
- The owner’s testing pages describe six EMC immunity methods, emissions measurements, qualitative climatic testing and IMV G240 random, sine and shock testing.
- Testing enquiry route
- Use compliance.pmuk@eu.panasonic.com or +44 29 20542120. The current contact page labels these as EMC testing enquiries, and the testing-services page publishes the same route.
- Management-system evidence
- The owner says its laboratories operate under the ISO/IEC 17025 laboratory management system. No current accredited site/method schedule was verified in the inspected owner pages.
Testing capabilities
Owner-listed EMC immunity methods
The owner lists ESD to EN 61000-4-2, radiated immunity to -4-3, electrical fast transient/bursts to -4-4, surge to -4-5, conducted immunity to -4-6, and voltage dips/short interruptions to -4-11. No edition, applied level or universal product scope is supplied.
Emissions measurements in semi-anechoic chambers
The owner describes two semi-anechoic chambers for emissions measurements at 3 m and prints three measurement bands: 9 kHz–30 MHz, 30 MHz–1 GHz and 1–18 GHz. These are published measurement ranges rather than an unrestricted radiated or immunity scope. Confirm the method and configuration for the product.
Owner-published climatic testing
The reliability page describes climatic testing across heat, cold, humidity and pressure scenarios, with its equipment located at one site. No numerical chamber or conditioning envelope is allocated in this guide. Confirm the required conditions, specimen and programme.
IMV G240 vibration and shock testing
The owner identifies an IMV G240 system and lists random, sine and shock test characteristics in the X, Y and Z axes, with maximum frequency 2,600 Hz. Horizontal and vertical platform working areas are published separately. Specimen, fixture, load and achievable test conditions need agreement.
Equipment and published limits
| Specification | Published value | Conditions |
|---|---|---|
| Published emissions distance and bands | Two chambers, 3 m, bands 9 kHz–30 MHz, 30 MHz–1 GHz and 1–18 GHz | Owner measurement statements, without accuracy, immunity level or every-method coverage inferred. Separate bands are retained. |
| HTML-backed vibration frequency | IMV G240 maximum frequency 2,600 Hz | Owner system statement with random, sine and shock modes. No generic image-table force, acceleration or velocity is allocated to this model. |
| Published working areas | Horizontal slip table 600 × 600 mm, vertical platform 600 × 500 mm | Working-area statements, not permissible specimen mass, complete fixture clearance or an all-axis simultaneous test envelope. |
Access and contact
Use the dedicated compliance email or testing phone to ask about the proposed customer work. The owner lists the Cardiff site and separately publishes info.pmuk@eu.panasonic.com and +44 29 20540011 for general enquiries. Agree the product, method, configuration, fixture, conditioning, acceptance criteria, witnessing, report requirements, quotation and programme with the provider.
Facility contact
- Address
- Pentwyn Industrial Estate
Cardiff, CF23 7XB
United Kingdom - Telephone
- +44 29 20542120
- Website
- Official test house website
Standards and accreditation
- Published EMC methods
- The six EN 61000 immunity references are owner-listed method families without verified editions or test levels. The emissions description supplies distance and separate measurement bands, rather than a current accredited method schedule.
- ISO/IEC 17025 owner statement
- The owner’s laboratory management-system wording does not verify current UKAS accreditation, a particular accredited method, report status or certification outcome. Confirm the required status with the provider.
What to confirm with the facility
- The published emissions bands and 3 m distance, G240 maximum frequency and platform working areas are separate owner statements. No general product-size, load, accuracy, immunity level or combined maximum is inferred.
- The current Cardiff contact block does not verify an additional street, and the ISO/IEC 17025 management-system statement does not establish an accredited site/method scope. Imported directory roles, contacts and coordinates are not retained.
- Provide the test objective, product and fixture configuration, exact methods and conditions, reporting and timing so the provider can confirm suitability and cost.
Before requesting a test
Public information not available. Contact test facility provider for more information.
Frequently asked questions
Public information not available. Contact test facility provider for more information.
Related testing facilities
Public information not available. Contact test facility provider for more information.
Further reading
Public information not available. Contact test facility provider for more information.
Sources and review
Reviewed by Arc on 1 October 2026 in Europe/London using five fresh official owner pages. Exact Cardiff contact identity and testing route, selected EMC/climatic/vibration services and HTML-backed limits are mapped. Original titles, canonicals, absent page dates, body/header/retrieval records and text inspections are preserved. Two page-referenced table images were also captured and visually inspected as supporting evidence. The vibration image names i240 models rather than the HTML G240 and has incomplete footnotes, so velocity and all image-only numerical claims are omitted. No evidence contract change was made. The owner ISO/IEC 17025 management-system statement is not a current accreditation schedule. Prior discovery remains unchanged, and no imported street, present-role claim or coordinates are inferred.
Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.
Panasonic Manufacturing UK testing services
The owner describes testing laboratories and names EMC, product safety, materials, RoHS and reliability groups. This guide selects the supported EMC and reliability pages. The ISO/IEC 17025 laboratory management-system statement does not establish a current UKAS method/site accreditation. The compliance email and phone are testing routes, with no separately verified present-person role. No publication or modification date was verified.
Panasonic Manufacturing UK contact page
The owner lists Pentwyn Industrial Estate, Cardiff CF23 7XB, United Kingdom. EMC enquiries use compliance.pmuk@eu.panasonic.com and 029 20542120. General info and phone are separate. No Wyncliffe Road, imported emc mailbox or current named-person role is added. The original canonical is the page URL and no verified page dates were found.
Panasonic Manufacturing UK EMC testing
The page lists six EN 61000 immunity method families, without editions or test levels. It describes two semi-anechoic chambers, 3 m emissions measurements and three printed measurement ranges. Those ranges do not establish every radiated/immunity method over one continuous spectrum. Microwave APD experience is separate context. No current method accreditation or measurement accuracy is inferred. No page dates were verified.
Panasonic Manufacturing UK environment and reliability testing
The HTML describes climatic testing and an IMV G240 system with maximum 2,600 Hz, X/Y/Z axes, random/sine/shock modes and horizontal/vertical working areas. The velocity is omitted because the separately inspected system image names different i240 models with incomplete footnotes. Both referenced images are preserved as supporting inspection, with no image-only numerical chamber, velocity, force or acceleration claims added. No page dates were verified.
Panasonic Manufacturing UK homepage
The homepage names Panasonic Manufacturing UK and links its customer testing services. Appliance and non-invasive medical-device manufacturing are not additional testing or approval scope. Its original canonical omits the trailing slash. Copyright 2025 does not establish a page publication date, and no verified page dates were found.