Skip to content

Raymarine Marine House EMC laboratory, Fareham

Raymarine UKFareham, Hampshire

UKAS lists Raymarine UK at Marine House, Fareham. Schedule 28891, issue 001 dated 9 July 2025, covers eight civil EMC methods at that address only. Raymarine’s current contact page uses Teledyne Raymarine UK for the same office. The guide retains the exact scheduled scope and separate published contact routes. External laboratory access and the imported environmental equipment claims remain unverified.

Reviewed by Arc · About this review

Key facts

Exact site and operator
Marine House, Cartwright Drive, Fareham, Hampshire PO15 5RJ. UKAS lists Raymarine UK, while the current owner contact page names Teledyne Raymarine UK at the same office.
Scheduled testing
Schedule 28891, issue 001 dated 9 July 2025, lists eight civil EMC methods under ISO/IEC 17025:2017. Testing is restricted to the stated Marine House address.
Published enquiry
The schedule lists Neil Millerchip and Neil.Millerchip@raymarine.com, without a verified current job title. The owner publishes +44 1329 246700 for its UK office and product support. External laboratory access needs confirmation.

Testing capabilities

Conducted emissions

Schedule 28891 lists conducted emissions from 9 kHz to 30 MHz at Marine House.

Radiated emissions

Schedule 28891 lists radiated emissions from 9 kHz to 6 GHz at Marine House.

Electrostatic discharge immunity

Schedule 28891 lists ESD immunity up to 15 kV at Marine House.

Radiated electromagnetic field immunity

Schedule 28891 lists radiated immunity from 80 MHz to 6 GHz at 10 V/m at Marine House.

Fast transient and burst immunity

Schedule 28891 lists fast transient and burst immunity up to 4.0 kV at Marine House.

Surge immunity

Schedule 28891 lists surge immunity up to 4.0 kV at Marine House.

Conducted RF immunity

Schedule 28891 lists conducted RF immunity from 150 kHz to 80 MHz at 10 V rms at Marine House.

Voltage dips, interruptions and fluctuations

Schedule 28891 lists voltage dips, interruptions and fluctuations immunity at Marine House, with row-specific IEC references.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
Conducted emissions9 kHz to 30 MHzPublished scope for this named method in issue 001. Confirm the applicable standard edition, item and configuration with the laboratory.
Radiated emissions9 kHz to 6 GHzPublished scope for this named method in issue 001. Confirm the applicable standard edition, item and configuration with the laboratory.
ESD immunityUp to 15 kVPublished scope for this named method in issue 001. Confirm the applicable standard edition, item and configuration with the laboratory.
Radiated field immunity80 MHz to 6 GHz at 10 V/mPublished scope for this named method in issue 001. Confirm the applicable standard edition, item and configuration with the laboratory.
Fast transient and burst immunityUp to 4.0 kVPublished scope for this named method in issue 001. Confirm the applicable standard edition, item and configuration with the laboratory.
Surge immunityUp to 4.0 kVPublished scope for this named method in issue 001. Confirm the applicable standard edition, item and configuration with the laboratory.
Conducted RF immunity150 kHz to 80 MHz at 10 V rmsPublished scope for this named method in issue 001. Confirm the applicable standard edition, item and configuration with the laboratory.

Access and contact

The UKAS schedule lists Neil Millerchip at Neil.Millerchip@raymarine.com and +44 1329 246700. This verifies the published schedule contact without a current role claim. Raymarine’s current page gives the same UK office/product-support phone and general enquiry routes. Confirm whether external work is accepted, the exact method and configuration, report status and timing before planning a test.

Facility contact

Address
Marine House, Cartwright Drive
Fareham, Hampshire, PO15 5RJ
United Kingdom

Standards and accreditation

UKAS schedule 28891
The current register lists Raymarine UK, Testing Laboratories 28891. The retrieved ISO/IEC 17025:2017 schedule is issue 001 dated 9 July 2025, with eight EMC methods at Marine House only. Accreditation applies to the listed scope.
Row-specific EMC references
The schedule supplies IEC 60945:2002 with its 2008 corrigendum and specified EN 55016, CISPR 16 and IEC 61000 references. Editions and sections differ by method. Check the exact row and required report rather than treating every edition as applicable to every test.

What to confirm with the facility

  • The checked official sources do not verify environmental test rigs at Marine House. The current Raymariner article describes a vessel based in Warsash, which does not establish local vibration, drop, temperature, rain, submersion or salt-mist methods.
  • Published EMC ranges are separate method-specific scope limits. They do not establish one combined operating envelope, item capacity, external access or a certification outcome.
  • Provide the item, operating mode, dimensions, interfaces, cabling, proposed method/edition, acceptance criteria and report requirements so the laboratory can assess the work.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Reviewed by Arc on 1 October 2026 in Europe/London using five fresh official captures. Both complete pages of UKAS schedule 28891 were extracted and visually inspected, with original PDF metadata, issue/date, images and rendering provenance retained. Eight exact EMC rows and the Marine House-only restriction are mapped. The focused q=Raymarine register result corroborates Raymarine UK and the schedule link. The earlier search=Raymarine query returned No results because it did not use the official form field, with no withdrawal inferred. The current owner’s Teledyne name is disclosed separately. Neil Millerchip is a schedule-listed contact without a current role claim, and the office/product-support route does not establish external access. The 26 January 2026 Raymariner article is Warsash vessel context, with no environmental equipment or working cadence transferred to Fareham. Template dates, article publication, PDF creation/modification and schedule issue are separate from retrieval/review. Four prior discovery captures remain unchanged, three official body pairs are byte-identical and the third-party article is preserved without reliance. Inherited coordinates are cleared.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. 28891Testing Single

    United Kingdom Accreditation Service · Reviewed

    UKAS schedule 28891, issue 001 dated 9 July 2025, names Raymarine UK and confines its eight civil EMC rows to Marine House. Original two-page PDF, metadata, extraction and complete visual inspection retained. This is the scheduled scope, not external access or environmental testing.

  2. Contact Us | Raymarine UK

    Raymarine · Reviewed

    Current owner page names Teledyne Raymarine UK at Marine House and publishes UK product support, office phone and sales/general enquiry routes. This wording differs from the UKAS operator name and is retained explicitly. No dedicated external laboratory booking or current named role is inferred.

  3. Raymariner: Real‑World Testing for Reliable Marine Electronics | Raymarine

    Raymarine · Reviewed

    Article published 26 January 2026 describes the Raymariner vessel based in Warsash. It does not allocate vibration, drop, temperature, rain, submersion or salt-mist equipment to Marine House. Vessel working cadence and transducer swaps are not local laboratory limits or booking availability.

  4. Search UKAS accredited organisations

    United Kingdom Accreditation Service · Reviewed

    Preserved initial search=Raymarine query returned No results. The official form uses q, so this ineffective query is not evidence of withdrawal or absence.

  5. Search UKAS accredited organisations

    United Kingdom Accreditation Service · Reviewed

    Focused official q=Raymarine query lists Raymarine UK, Testing Laboratories 28891, Marine House and the schedule link. This supports the exact current register identity without extending the scheduled methods, operator name or access.