UKAS schedule 29722 identifies Retronix at North Caldeen Road, Coatbridge, ML5 4EF, accredited to ISO/IEC 17025:2017, with testing performed at that address only. Its listed scope covers SAE AS6171:2018 test methods for EEE parts to mitigate suspect/counterfeit risk. Retronix’s current homepage publishes the Coatbridge UK contact route.

Reviewed by Arc · About this review

Key facts

UKAS-listed Coatbridge testing address
UKAS schedule 29722, issue 003 dated 16 September 2025, identifies Retronix at North Caldeen Road, Coatbridge, ML5 4EF, accredited to ISO/IEC 17025:2017, and says testing is performed at that address only.
Detailed listed EEE-parts scope
The UKAS schedule lists SAE AS6171:2018 suspect/counterfeit test-evaluation methods for electrical, electronic and electromechanical (EEE) parts to mitigate the risk of receiving or using suspect/counterfeit EEE parts.
Published UK information route
Retronix publishes North Caldeen Rd, Coatbridge, Scotland, ML5 4EF, sales@retronix.com and +44 (0) 1236 433 345 for its UK operation.

Testing capabilities

UKAS-listed suspect/counterfeit EEE-parts evaluation

UKAS schedule 29722 lists SAE AS6171:2018 suspect/counterfeit test-evaluation methods for electrical, electronic and electromechanical (EEE) parts, stated as mitigating the risk of receiving or using suspect/counterfeit EEE parts.

Listed AS6171 visual, XRF, physical, radiological and electrical methods

The schedule lists AS6171/2 external visual inspection, remarking/resurfacing and surface texture, excluding Method F (SEM); AS6171/3 XRF analysis of Pb, Cu, Zn, Ni, Ag and Sn; AS6171/4 delid/decapsulation physical analysis; AS6171/5 radiological (X-ray) testing; and AS6171/7 electrical testing and temperature cycling for active parts.

Equipment and published limits

Public information not available. Contact test facility provider for more information.

Access and contact

Retronix publishes its UK information route as North Caldeen Rd, Coatbridge, Scotland, ML5 4EF; sales@retronix.com; and +44 (0) 1236 433 345. UKAS schedule 29722 identifies Retronix’s testing at North Caldeen Road, Coatbridge, ML5 4EF only. Confirm the applicable scope entry, requested configuration, availability, price, lead time and item acceptance directly with Retronix.

Facility contact

Address
North Caldeen Road
Coatbridge, Scotland, ML5 4EF

Standards and accreditation

ISO/IEC 17025:2017 accreditation
UKAS schedule 29722 identifies Retronix as accredited to ISO/IEC 17025:2017 at North Caldeen Road, Coatbridge, ML5 4EF, with testing performed at that address only. The accreditation is limited to the schedule’s detailed listed SAE AS6171:2018 EEE-parts scope: AS6171/2 external visual inspection, remarking/resurfacing and surface texture, excluding Method F (SEM); AS6171/3 XRF analysis of Pb, Cu, Zn, Ni, Ag and Sn; AS6171/4 delid/decapsulation physical analysis; AS6171/5 radiological (X-ray) testing; and AS6171/7 electrical testing and temperature cycling for active parts. It does not establish accreditation for all Retronix services or a requested configuration.

What to confirm with the facility

Public information not available. Contact test facility provider for more information.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Arc reviewed the linked Retronix page and UKAS schedule 29722 on 30 September 2026 by direct HTTP retrieval. This is a review of published information, not a laboratory inspection, test witnessing or confirmation of availability. Confirm the applicable scope, requested configuration and booking terms directly with Retronix.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. Chip Recovery, Reballing, Alloy Conversion & Authenticity Testing

    Retronix · Reviewed

    First-party page used for Retronix’s published UK address, email and telephone. It does not establish booking availability, capacity, commercial terms, item acceptance or the detailed accreditation scope.

  2. Schedule of Accreditation 29722: Retronix

    United Kingdom Accreditation Service · Reviewed

    UKAS schedule used for the legal entity, Coatbridge testing address, ISO/IEC 17025:2017 statement and detailed listed SAE AS6171:2018 EEE-parts scope. It does not establish booking availability, capacity, commercial terms, item acceptance or accreditation beyond that listed scope.