Rhymney environmental testing laboratory
Rhymney Test EquipmentRhymney
UKAS lists Rhymney Test Equipment at Unit 19, Heads of the Valleys Industrial Estate, Heol Klockner, Rhymney. Testing schedule 22985 issue 004 dated 23 June 2025 covers dry heat, cold, temperature change or thermal shock, humidity and salt spray at that address only. Method-specific ranges and chamber limits apply. The owner website currently returns suspended-hosting content, so the guide uses the official testing register and schedule for scope and contact.
Reviewed by Arc · About this review
Key facts
- Exact test site
- Unit 19, Heads of the Valleys Industrial Estate, Heol Klockner, Rhymney NP22 5RL. UKAS testing register 22985 and its schedule identify Rhymney Test Equipment at this address.
- Local testing scope
- The schedule covers five environmental methods for general non-explosive materials and equipment. Testing is restricted to the stated address. The separate calibration register entry does not expand these testing methods.
- Published enquiry and website status
- The schedule lists Craig Journeaux, craig@testinghouse.co.uk and +44 1685 708870, without a verified current job title. Both owner website seeds return suspended-hosting content. This is a website access failure and does not establish facility closure or booking availability.
Testing capabilities
Dry heat
The Unit 19 schedule lists constant or cyclic dry heat with a maximum +180 °C and a maximum chamber size of 1.5 m × 2.4 m × 1.5 m.
Cold testing
The Unit 19 schedule lists constant or cyclic cold tests with a minimum -70 °C and a maximum chamber size of 1.5 m × 2.4 m × 1.5 m.
Change of temperature and thermal shock
The Unit 19 schedule lists change of temperature or thermal shock from -65 °C to +120 °C, with a maximum chamber size of 1.5 m × 2.4 m × 1.5 m.
Humidity testing
The Unit 19 schedule lists constant or cyclic humidity, publishing 10% to 98% RH and -10 °C to +85 °C with a maximum chamber size of 1.0 m × 1.0 m × 1.0 m. Confirm the achievable combination and profile.
Salt spray corrosion conditioning
The Unit 19 schedule lists cyclic or steady-state salt spray corrosion work with a maximum chamber size of 1.0 m × 0.7 m × 1.5 m. Its ISO 9227:2022 entry is conditioning only.
Equipment and published limits
| Specification | Published value | Conditions |
|---|---|---|
| Dry heat | Maximum +180 °C, maximum chamber 1.5 m × 2.4 m × 1.5 m | Constant or cyclic dry-heat row. Confirm the exact profile, item and method. Separate from other test limits. |
| Cold testing | Minimum -70 °C, maximum chamber 1.5 m × 2.4 m × 1.5 m | Constant or cyclic cold-test row. This is not the thermal-shock lower endpoint. Confirm configuration. |
| Change of temperature and thermal shock | -65 °C to +120 °C, maximum chamber 1.5 m × 2.4 m × 1.5 m | Specific temperature-change/thermal-shock row, with exact test profile and item to agree. |
| Humidity | 10% to 98% RH and -10 °C to +85 °C, maximum chamber 1.0 m × 1.0 m × 1.0 m | Separate published ranges do not guarantee every simultaneous temperature and humidity combination. Confirm achievable conditions and profile. |
| Salt spray chamber | Maximum chamber 1.0 m × 0.7 m × 1.5 m | Cyclic or steady-state salt corrosion row. ISO 9227:2022 is conditioning only, without a results/certification outcome guarantee. |
Access and contact
Use the schedule-published craig@testinghouse.co.uk or +44 1685 708870 to request information. Craig Journeaux is the schedule-listed contact without a current role claim. The owner website is unavailable beyond suspended-hosting content. Confirm that the enquiry route works and agree the exact test, item, conditions, reporting and timing. No booking availability or unrestricted external access is verified.
Facility contact
- Address
- Unit 19, Heads of the Valleys Industrial Estate, Heol Klockner
Rhymney, NP22 5RL
United Kingdom - Telephone
- +44 1685 708870
- Website
- Official test house website
Standards and accreditation
- UKAS testing 22985
- The current testing register identifies Rhymney Test Equipment at Unit 19. ISO/IEC 17025:2017 schedule issue 004 dated 23 June 2025 confines the listed testing to that address. The calibration register entry is separate and its method scope is not assessed here.
- Temperature methods
- Dry heat names BS EN 60068-2-2:2007 Test B, cold names BS EN 60068-2-1:2007 Test A, and temperature change names BS EN 60068-2-14:2023 Tests Na and Nb. The exact rows also list DEF STAN issue-specific references and MIL STD 810 G/H Methods 501, 502 and 503 respectively.
- Humidity methods
- The humidity row names BS EN 60068-2-30:2005 Test Db, BS EN 60068-2-78:2013 Test Cab, BS EN 60068-2-38:2021 and its specified DEF STAN/MIL STD 810 references. Confirm the exact method, profile and simultaneous conditions.
- Salt spray and conditioning scope
- The salt row lists BS EN 60068-2-11:2021 Test Ka, ASTM B117-19, BS EN 60068-2-52:2018 and its specified DEF STAN/MIL STD 810 references. ISO 9227:2022 is expressly conditioning only. Scope does not guarantee a product certification outcome.
What to confirm with the facility
- Dry heat, cold, thermal shock, humidity and salt corrosion have separate published ranges and chamber dimensions. Humidity’s stated temperature and RH ranges do not establish every simultaneous combination. Confirm item capacity, profile and achievable conditions.
- ISO 9227:2022 is conditioning only in the salt row. The testing schedule does not establish the separately listed calibration scope, current booking availability or certification outcome.
- Both checked owner URLs return suspended-hosting pages. The regulator-published contact remains an information route to verify, without an inference that the facility has closed or the route is presently responsive.
- Provide item dimensions and mass, material/product, profile, method edition, exposure duration, acceptance criteria, monitoring and report requirements before agreeing work.
Before requesting a test
Public information not available. Contact test facility provider for more information.
Frequently asked questions
Public information not available. Contact test facility provider for more information.
Related testing facilities
Public information not available. Contact test facility provider for more information.
Further reading
Public information not available. Contact test facility provider for more information.
Sources and review
Reviewed by Arc on 1 October 2026 in Europe/London using four fresh official captures. Both owner seeds return HTTP 200 suspended-hosting pages, preserved with requested/effective URLs and redirect provenance as failed content. They supply no facility facts or closure/status proof, and the hosting webmaster is not a testing enquiry. The current q=Rhymney register lists exact testing 22985 and a separate calibration entry, with no calibration methods transferred. Both complete testing-schedule pages were extracted, rendered and visually inspected. Issue 004 is dated 23 June 2025, PDF creation/modification are 26 June 2025 and register template dates are separate from review. Five exact local methods, row-specific limits/dimensions, humidity combination qualification and ISO 9227 conditioning-only scope are mapped. Craig Journeaux and craig@testinghouse.co.uk are schedule-published enquiry details without a current role or availability claim. Imported info email, mirror active status and coordinates are cleared. Original titles, canonicals, dates, bodies, headers, retrieval and PDF provenance remain intact. All three prior discovery bodies are byte-identical to fresh responses. The official register is the useful web destination while owner content is unavailable.
Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.
Testing schedule 22985 issue 004 dated 23 June 2025 lists five environmental methods at Unit 19 only. Original PDF creation/modification 26 June 2025, both complete pages extracted/rendered/inspected. Humidity ranges are not a guaranteed combined envelope and ISO 9227:2022 is conditioning only. No calibration scope, external access or certification outcome inferred.
Search UKAS accredited organisations
q=Rhymney lists Rhymney Test Equipment Testing Laboratories 22985 at Unit 19, exact phone and testing schedule link. A separate calibration entry is present but its methods are outside this guide. Template dates do not date the particular result. Protected register email is not decoded.
Exact HTTPS owner seed redirects to an Account Suspended hosting page, HTTP 200. Retained as access failure only, with original requested/effective URLs and all redirect headers. It supplies no facility facts, closure/status proof, test access or legitimate laboratory enquiry. Hosting webmaster is not substituted for the schedule contact.
Exact HTTP www owner seed redirects to the same suspended-hosting content, HTTP 200. Original URL/redirect/body metadata preserved as failed content. No closure or accreditation withdrawal inferred and no hosting webmaster contact published as a test route.