Rivencore Global Solutions’s current register result and schedule 28772 identify the testing laboratory at 19 Witney Road, Poole. The retained scope covers climatic exposure, ingress protection and specified mechanical tests for listed non-explosive products. Published schedule conditions are used here. The owner advertises a wider portfolio and separately labels Fleets Point as headquarters.

Reviewed by Arc · About this review

Key facts

Exact testing site
19 Witney Road, Nuffield Industrial Estate, Poole, Dorset BH17 0GL. Schedule 28772 issue 008 dated 16 September 2026 states testing at this address only.
Products in scope
The schedule lists non-explosive lighting equipment, optical projection units, LCD units, control and metrological equipment, electronic components and navigation equipment.
Published enquiry
greg.hole@rivencoreglobal.com and +44 1202 119367. Greg Hole is the schedule-listed contact without a verified present job title. The owner offers a general enquiry form with a Testing selection.

Testing capabilities

Dry heat and low temperature

The schedule lists separate dry-heat tests up to +170 °C and low-temperature tests down to -60 °C, each with a 0.9 m × 1.0 m × 1.6 m chamber. Exact BS EN 60068, BS EN 60945 and MIL-STD 810H methods and conditions apply.

Change of temperature

BS EN 60068-2-14:2023 Test Na is listed from -60 °C to +170 °C with maximum ramp rate 3 °C/min and a 0.9 m × 1.0 m × 1.6 m chamber. Confirm the required profile and item setup.

Temperature with humidity

Steady-state and cyclic humidity testing has separately stated temperature limits of -60 °C to +170 °C and humidity limits of 15% to 98% RH. These do not establish every simultaneous combination. An unresolved 2025 standard-reference numbering error is omitted without correction.

Solid and liquid ingress protection

BS EN 60529:1992+A2:2013 scope lists solids IP1X to IP6X and liquids IPX1 to IPX8. IPX7 specifies temporary immersion at 1 m. IPX8 lists continuous immersion without a depth or capacity figure. Agree the exact level and conditions.

Mechanical strength and impact

The schedule lists IEC 62368-1 strength tests under clauses T.2, T.4 and T.5, plus impact under T.6. The 2024+A11:2024 impact row specifies horizontal surfaces. These are specified parts of the standard.

Free-fall drop tests

IEC 62368-1 clause T.7 is listed for free-fall drop testing, with maximum item mass 15 kg and maximum drop height 1.3 m. Exact setup and acceptance requirements must be agreed.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
Dry-heat and cold method limitsDry heat maximum +170 °C, cold minimum -60 °C. Each row lists 0.9 m × 1.0 m × 1.6 m.Separate scheduled methods and conditions. Chamber dimensions are not a test-item capacity or simultaneous operating envelope.
Change of temperature-60 °C to +170 °C, maximum ramp 3 °C/min, chamber 0.9 m × 1.0 m × 1.6 mBS EN 60068-2-14:2023 Test Na schedule row. Wider owner chamber ratings are not substituted.
Temperature and humidity rangesTemperature -60 °C to +170 °C, humidity 15% to 98% RHSeparate published ranges, without a guaranteed combined envelope. The humidity dimension has an incomplete final unit and is omitted.
Specific ingress conditionsIP4X test wire 1.0 mm diameter, IPX2 tilt up to 15°, IPX7 temporary immersion 1 mBS EN 60529 schedule rows. IPX8 is continuous immersion with no published depth or item-capacity figure.
Free-fall drop limitsMaximum item mass 15 kg, maximum drop height 1.3 mIEC 62368-1 clause T.7 row only, no transfer to other mechanical or environmental tests.

Access and contact

Contact the scheduled laboratory through greg.hole@rivencoreglobal.com or +44 1202 119367, or use the owner’s general enquiry form with Testing selected. Greg Hole is schedule-listed without a present role claim. Confirm work and delivery to 19 Witney Road, BH17 0GL. The owner’s Fleets Point, BH15 3SS contact address is labelled headquarters. Current availability, item acceptance and reporting require agreement.

Facility contact

Address
19 Witney Road, Nuffield Industrial Estate
Poole, Dorset, BH17 0GL
United Kingdom

Standards and accreditation

UKAS 28772 and ISO/IEC 17025:2017
The current exact register lists Rivencore Global Solutions Testing Laboratories 28772 at 19 Witney Road. Schedule issue 008 is dated 16 September 2026 and confines testing to that main address. No imported mirror status or relocation claim is retained.
Exact climatic methods
Dry heat lists BS EN IEC 60068-2-2:2025 Test B, BS EN 60068-2-2:2007 Test B, BS EN 60945:2002 clause 8.2 and MIL-STD 810H method 501.7. Cold lists BS EN IEC 60068-2-1:2025 Test A, BS EN 60068-2-1:2007 Test A, BS EN 60945:2002 clause 8.4 and MIL-STD 810H method 502.7. Change of temperature uses BS EN 60068-2-14:2023 Test Na.
Qualified humidity references
Retained humidity references are BS EN 60068-2-30:2005, BS EN 60945:2002 clause 8.3, MIL-STD 810H method 507.6, IEC 62368-1:2018 revised clause 5.4.8 and IEC 62368-1:2024+A11:2024 clause 5.4.8. The source’s unresolved 2025 numbering error is retained in evidence and omitted without correction.
Ingress and mechanical methods
Ingress uses BS EN 60529:1992+A2:2013. Mechanical testing lists IEC 62368-1:2018 and IEC 62368-1:2024+A11:2024 strength T.2/T.4/T.5, impact T.6 and drop T.7. The 2024 impact row is horizontal surfaces only. No complete-standard certificate is inferred.
Wider advertised portfolio
The owner advertises wider climatic ratings and HALT testing. They are separate from the exact scheduled limits retained here and do not establish blanket accreditation.

What to confirm with the facility

  • Use the current schedule/register testing address at 19 Witney Road. The owner labels Fleets Point as headquarters. Confirm delivery without inferring a relocation, closure or accreditation status change.
  • Confirm the simultaneous temperature/humidity condition. The guide retains separate ranges and omits the humidity dimension with an incomplete final unit and the unresolved 2025 standard-reference numbering error.
  • Confirm the exact IP level, immersion depth/duration and drop setup. IPX8 has no depth figure. Maximum 15 kg and 1.3 m apply to the free-fall row only.
  • Provide item dimensions, mass, sample quantity, fixtures, operating state, target method and edition, acceptance criteria, reporting needs and preferred dates.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Reviewed by Arc on 1 October 2026 in Europe/London using five fresh official captures. The current exact 28772 register and two-page schedule agree on 19 Witney Road, Poole. Both complete PDF pages were extracted, rendered and visually inspected. Issue 008 is dated 16 September 2026, while PDF creation/modification are 17 September 2026. Current owner contact labels Fleets Point as headquarters, without a relocation inference. Exact scheduled climatic, ingress and mechanical scope replaces the imported ingress-only summary. Humidity ranges remain separate, the incomplete humidity dimension and original 2025 numbering error are preserved in evidence and omitted without correction. IPX8 has no depth guarantee, and drop limits are method-specific. Wider owner equipment ratings and HALT remain outside retained accredited claims. Greg Hole is schedule-listed without a current role claim. Original titles, canonicals, publisher dates, bytes, headers and provenance are retained. Both prior owner/schedule bodies are identical. Imported mirror withdrawal, generic headquarters phone as laboratory contact and postcode coordinates are cleared.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. Rivencore Global - Home

    Rivencore Global Solutions · Reviewed

    Current four-division maritime engineering homepage links official testing and UK enquiry pages. Product resilience descriptions are not laboratory testing scope or whole-product certification.

  2. Rivencore Global - Testing

    Rivencore Global Solutions · Reviewed

    Owner explicitly locates testing in Poole and advertises environmental, ingress and mechanical testing plus wider chamber ratings and HALT. Retained quantitative scope follows current schedule 28772. Wider owner ratings and HALT are not transferred into accredited conditions.

  3. Rivencore Global - Contact

    Rivencore Global Solutions · Reviewed

    Owner labels Fleets Point BH15 3SS and +44 1202 307007 as UK/global headquarters. It supplies a general form with Testing selection, without identifying headquarters as the exact current accredited laboratory. Schedule/register 19 Witney Road address and schedule enquiry are retained.

  4. Search UKAS accredited organisations

    United Kingdom Accreditation Service · Reviewed

    Exact current result is Rivencore Global Solutions Testing Laboratories 28772 at 19 Witney Road, Nuffield Industrial Estate, Poole BH17 0GL with phone +44 1202 119367. Imported mirror withdrawal is not repeated and no unconditional status or relocation inference is made.

  5. 28772Testing Single

    United Kingdom Accreditation Service · Reviewed

    Issue 008 dated 16 September 2026, exact 19 Witney Road site only. Both complete pages inspected. Exact climatic, ingress and IEC 62368 mechanical rows retained. Humidity ranges are separate. The erroneous 2025 humidity standard number and incomplete final dimension unit are preserved but omitted without correction. IPX8 has no depth guarantee.