Skip to content

SATRA Kettering testing laboratory

SATRA Technology CentreKettering, Northamptonshire

SATRA Technology Centre’s Kettering laboratory is location UK in current testing schedule 0248 issue 105. Selected local rows cover material tests, footwear, protective clothing, floor coverings/furniture, fall-protection equipment and construction products. Customer/general sites S1 and IKAR GmbH in Germany S2 are separately allocated. Exact product, method, edition and exclusions control the scope.

Reviewed by Arc · About this review

Key facts

Exact testing laboratory
Wyndham Way, Telford Way Industrial Estate, Kettering, Northamptonshire NN16 8SD. Current register 0248 and schedule issue 105 dated 11 September 2026 identify the UK laboratory.
Separate locations and activities
UK is the Kettering laboratory, S1 customer premises/general sites and S2 IKAR GmbH, Fulda, Germany. Testing register 0248 is distinct from the separately listed certification body and Dongguan laboratory.
Published contact
info@satra.com and +44 1536 410000 are printed in the current schedule. J Glasspool and Kelly Harrison are schedule-listed contacts, without verified present job titles.

Testing capabilities

Clothing, textile and leather material tests

Selected UK rows include dimensional change, domestic/industrial washing, material-specific colourfastness, flexing, abrasion and thermal/water-vapour resistance. Chemical rows separately cover named textile or leather analytes such as azo-derived amines, pH, formaldehyde and chromium VI. Exact material and method must be agreed.

Footwear, rubber and plastics physical tests

Local footwear rows include adhesive/sole bond strength, heel and attachment tests, dynamic water penetration and flexing. Rubber/thermoplastic-soling abrasion uses ISO 4649:2017 Method A. Durometer hardness uses SATRA TM205:2016 for Shore A only. No general hardness range or full safety-footwear approval is inferred.

Selected heat, flame and welding clothing tests

UK test-data scope for EN ISO 14116:2015 excludes burst strength. EN ISO 11612:2015 excludes burst strength, aluminium splash, iron splash and mechanical pretreatment. EN ISO 11611:2015 excludes burst strength and small molten-metal spatter. Listed flame, heat, tensile, tear and seam methods remain product-specific.

Floor-covering and furniture performance tests

Selected UK rows cover flooring slip, abrasion, indentation, heat-related dimensional change and specified ignition tests, plus furniture/bedding strength, stability and ignitability. Pendulum testing is UK and S1, while the walking ramp is UK to DIN EN 16165:2021 Annex B. Flooring flexibility and electrical-resistance rows specify Method A only.

Specified harness, lanyard and rescue tests

UK rows include sit/full-body harnesses, lanyards, energy absorbers, connectors, rescue loops/harnesses and rescue lifting devices. EN 1496:2017 note 5.8 limits functional-testing measurement capability to less than 6.5 m. S1 and S2 allocations are separate, without transferring off-site-only methods to Kettering.

Construction thermal, corrosion and reaction-to-fire tests

UK rows include steady-state insulation testing by guarded hot plate, specified building-glass clause 8 tests and ISO 9227:2022+A1:2024 salt-spray testing for salt only. Specific building-product ignition, conditioning and classification rows are listed. BS EN 13501 classifications require recognised DIAP/EXAP and exclude expert judgements.

Equipment and published limits

Published equipment limits and conditions
SpecificationPublished valueConditions
Rubber/plastics hardness techniqueShore A only, SATRA TM205:2016Exact UK durometer row. No other Shore scale, numerical range or general equipment capacity is verified.
Rescue lifting-device functional measurementLess than 6.5 mExact EN 1496:2017 note 5.8 UK functional-testing measurement capability. No general tower height, fall distance or equipment envelope is established.
Insulation thermal-resistance techniqueGuarded hot plate, ISO 8302:1991UK flat-slab insulation row for steady-state thermal resistance and related properties. No temperature, specimen-size or chamber capacity figures verified.

Access and contact

Use the current schedule’s info@satra.com or +44 1536 410000. J Glasspool and Kelly Harrison are schedule-listed contacts without present-role claims. Agree the product/material, exact method/edition, UK or off-site allocation, exclusions, preparation and report. Current availability, sample quantities, turnaround and any separate certification route require direct confirmation.

Facility contact

Address
Wyndham Way, Telford Way Industrial Estate
Kettering, Northamptonshire, NN16 8SD
United Kingdom

Standards and accreditation

UKAS 0248 and limited flexible scope
Current testing register 0248 and schedule issue 105 dated 11 September 2026 identify the laboratory. UK flexible scope covers modification of existing methods, including revised/technically equivalent methods under documented procedure 17025 QP 31. It is not unrestricted accreditation or separate certification-body approval.
Protective-clothing scope exclusions
EN ISO 14116:2015 excludes burst strength. EN ISO 11612:2015 additionally excludes aluminium splash, iron splash and mechanical pretreatment. EN ISO 11611:2015 excludes burst strength and small molten-metal spatter. Material-specific listed test data do not establish complete product conformity.
Selected material and physical references
Examples include ISO 6330:2021 textile washing, EN ISO 11092:2014 thermal/water-vapour resistance, ISO 4649:2017 Method A soling abrasion, SATRA TM205:2016 Shore A hardness and EN 1496:2017 rescue-device functional measurement. Exact product row and edition apply.
Construction and fire-classification limits
ISO 8302:1991 applies to flat-slab insulation by guarded hot plate. Building-glass scope names EN 12150-1:2015 clause 8. ISO 9227:2022+A1:2024 is salt only. BS EN 13501-1:2018 classification follows recognised DIAP/EXAP, with expert judgements expressly excluded.
Method and edition restrictions
Flooring ramp slip uses DIN EN 16165:2021 Annex B, with pendulum testing separately allocated UK and S1. Flooring flexibility EN ISO 24344:2012 and electrical resistance EN 1081:2018 are Method A only. The schedule explicitly labels withdrawn older references, including ISO 3759:1984 and EN ISO 11925-2:2002/2010. No replacement is inferred.

What to confirm with the facility

  • Confirm UK, S1 or S2 for the exact method. Separate certification-body and overseas-laboratory results do not extend this Kettering testing scope or guarantee UKCA/CE certification.
  • Check the protective-clothing exclusions, material-specific methods and required edition. Limited flexible scope is tied to the documented procedure, and withdrawn references need agreement.
  • Confirm salt-only corrosion, Shore A-only hardness, flooring Method A restrictions and the rescue-device measurement condition. Fire classification excludes expert judgements and requires recognised DIAP/EXAP.
  • Provide the product/material, sample quantity and dimensions, preparation, exact method, acceptance criteria, reporting and preferred programme dates.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Public information not available. Contact test facility provider for more information.

Further reading

Public information not available. Contact test facility provider for more information.

Sources and review

Reviewed by Arc on 1 October 2026 in Europe/London using the current official testing register and thirty-two-page schedule. All complete PDF pages were extracted, rendered and visually inspected. Issue 105 is dated 11 September 2026, while PDF creation/modification are 14 September 2026. Six selected Kettering UK method groups are retained with exact exclusions, method restrictions and classification limits. S1/S2 locations, certification body and Dongguan laboratory remain separate. Published email/telephone and schedule contacts are retained without present-role or booking guarantees. The owner homepage redirected to new.satra.com and returned HTTP 403, which is preserved as a failed attempt and does not establish closure or absence of services. No access bypass was used. Original register title, canonical, template dates, bodies, headers and provenance are retained. Prior schedule bytes are identical. Prior and fresh owner attempts both returned 403, with different raw bodies preserved. Imported mirror status and postcode coordinates are cleared.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. Search UKAS accredited organisations

    United Kingdom Accreditation Service · Reviewed

    Exact SATRA Technology Centre Testing Laboratories 0248 result identifies Kettering NN16 8SD, telephone and owner website. Certification Bodies 5170, Dongguan laboratory 23671 and unrelated results are separate. Protected register email is not decoded.

  2. 0248Testing Multiple

    United Kingdom Accreditation Service · Reviewed

    Issue 105 dated 11 September 2026, all thirty-two complete pages inspected. UK is the Wyndham Way Kettering laboratory, S1 customer/general sites and S2 IKAR GmbH in Fulda. Guide retains six selected UK method groups, exact exclusions and classification limits, without allocating S1/S2-only rows or separate certification activities locally.