The University of Nottingham’s Power Electronics and Machines Centre (PEMC) is a purpose-built Jubilee Campus building for the Power Electronics, Machines and Control Research Institute. The University publishes high-power, power-electronics and drives laboratories and says its magnetic testing facility can be used by industry.
Reviewed by Arc · About this review
Key facts
- Published centre identity
- The University of Nottingham says the Power Electronics and Machines Centre, based on Jubilee Campus, is a purpose-built building for its Power Electronics, Machines and Control Research Institute.
- Published laboratory groups
- The University says the building is home to three purpose-built labs: High Power, Power Electronics and Drives.
- Published industry information route
- The University says the PEMCentre magnetic testing facility can be used by industry and directs companies to its Contact Form to discuss magnetic-testing capabilities and support.
Testing capabilities
Power-electronics, environmental and electromagnetic laboratories
The University lists a power-electronics laboratory with an environmental laboratory for component testing and simulation, an electromagnetic laboratory for electrically isolated study of electromagnetic effects, and a magnetics laboratory for magnetic-material testing and research.
High-power machine and drive testing
The University lists seven high-voltage, high-power custom interlocked and remote-controlled test cells for high-power, high-speed machine and drive testing in its Wolfson High Power Laboratory.
Magnetic testing for industry
The University says the PEMCentre is home to a magnetic testing facility that can be used by industry, and publishes developed test-set-up capabilities.
Equipment and published limits
| Specification | Published value | Conditions |
|---|---|---|
| Published high-power distribution capability | +20 MW | The University lists a multi-voltage distribution system with +20 MW power capability in the Wolfson High Power Laboratory. This is a published facility statement, not a guarantee of a particular test configuration, availability or acceptance. |
| Published magnetic-test operating-temperature ranges | Soft magnetic: -40°C to 180°C; hard magnetic: -40°C to 300°C | The University publishes these developed magnetic-test-set-up operating-temperature ranges. Confirm specimen type, test configuration, operating conditions, availability and acceptance directly with PEMC. |
| Published magnetic-test operating-stress ranges | Soft magnetic: 0 to 2 kN (C/T); hard magnetic: 0 to 1 kN (C) | The University publishes these developed magnetic-test-set-up operating-stress ranges, retaining C/T and C exactly as the source labels them. The guide does not expand those source abbreviations. Confirm specimen type, test configuration, operating conditions, availability and acceptance directly with PEMC. |
Access and contact
For magnetic-testing capabilities and support for company activities, the University directs users to the PEMC Contact Form. Confirm the relevant laboratory or test set-up, configuration, availability, safety requirements, price, lead time and acceptance directly with PEMC.
Facility contact
- Website
- Official test house website
Standards and accreditation
Public information not available. Contact test facility provider for more information.
What to confirm with the facility
Public information not available. Contact test facility provider for more information.
Before requesting a test
Public information not available. Contact test facility provider for more information.
Frequently asked questions
Public information not available. Contact test facility provider for more information.
Related testing facilities
Public information not available. Contact test facility provider for more information.
Further reading
Public information not available. Contact test facility provider for more information.
Sources and review
Arc reviewed the linked University of Nottingham pages on 30 September 2026 by direct HTTP retrieval. This is a review of published information, not a facility inspection, test witnessing or confirmation of availability. Confirm the requested test configuration and access terms directly with PEMC.
Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.
University page used for the centre’s published Jubilee Campus identity, purpose-built laboratories, environmental and electromagnetic laboratory descriptions, magnetic-material testing and research, and high-power test-cell statement. It does not establish a particular test configuration, availability, safety approval, price, lead time or acceptance.
Magnetics Testing Facility at PEMC
University page used for the magnetic-testing facility’s published industry-use statement, developed test-set-up ranges and Contact Form information route. It does not establish a general PEMC booking process, commercial terms, current availability, safety approval or acceptance of a particular test.